This device can be enrolled and programmed 
either before or after installation.
 
1.  Set the Lyric Controller in Programming 
Mode and go to Zone Programming. Select 
Add New, then Serial Number.  Follow the 
controller’s instructions to begin enrollment. 
2.  Remove the battery tab to activate the device 
and begin the enrollment process. 
3.  The Green [G1]
1
 LED flashes during 
enrollment (up to about 20 seconds*)  
*NOTE: Enrollment time varies depending on the 
signal strength between the device and the 
controller. 
•  The device sends its unique MAC ID 
(Serial Number) and Services information 
to the controller.   
•  The controller registers the device and 
displays the transmitter data on screen. 
4.  The Green [G1] LED is ON for 3 seconds 
and the controller beeps to confirm 
enrollment.  
5.  Trigger the detector as shown to complete 
enrollment. 
6.  Press SAVE. 
If the sensor is not successfully enrolled during 
the enrollment period, the LED turns off and the 
device powers down.  Activate the tamper, power 
down and up again, or use the FG-701 
Glassbreak Simulator to restart the enrollment 
process. 
The device can also be manually enrolled.  See 
the Controller’s Programming Guide for details. 
1
Refer to the SiXGB LEDs section. 
 
PULL
 
TO
CONNECT
Serial Number
Loop Number
Zone Description 1
Zone Description 2
Device Type
Response Type
Alarm Report
Chime
Supervision
Panic
Home
The Green LED
is ON for
3 seconds
1
2
4
Trigger the
device again
3
The Green LED 
flashes. Wait up to
about 20 seconds
30
0
45
20
10
PULL
 
TO
CONNECT
Programming Mode > Zones > 
     Add New > Serial Number 
/
5
Press SAVE
6
 
 
After enrolling, update the SiXGB firmware (via the Controller) 
to ensure the latest version is used.  See the Controller’s 
instructions. 
NOTE: Once enrolled in a system, the detector cannot be used with 
another controller until it is removed from the current controller. See the 
Controller’s instructions for details. 
 
Program the SiXGB  
Consult the Controller’s instructions for programming 
the device in the system. 
 
Adjust the detector sensitivity setting in the controller 
programming mode.  Refer to the table on the right for 
sensitivity options. 
 
Sensitivity Setting 
Approximate Range 
High* 
4.6-7.6m / 15-25 ft. 
Medium 
3-4.6m / 10-15 ft. 
Low 
1.5-3m / 5-10 ft. 
Lowest 
0-1.5m / 0-5 ft. 
*Factory default.  Change the sensitivity setting at 
the Controller.