Honeywell International Inc. 8DLLYNXREN-6 User Manual

Page of 80
 
 
- 79 - 
WEEKL
Y TESTING 
IS
REQ
UIRED T
O
 ENSURE
PR
OPER OPERA
TION
OF THIS 
SYSTEM
PREMISES
TELEPHONE
K10145X10 PLUG-IN
TRANSFORMER
9V
A
, 25V
A
EAR
T
H
GR
OUND
INCOMING
TELEPHONE
LINE
RING
TIP
RING
TIP
( )
( )
(+)
(+)
( )
T
O
 24HR 110V
A
UNSWITCHED
OUTLET
PIEZO
6-14VDC
120mA max.
(e
.g.
 W
A
VE2EX)
6-14VDC
30mA max.
D
ATA
OUT
SYNC
IN
POWERLINE
CARRIER DEVICES
GND
AC
AC
SYNC
COM
D
ATA
BELL
THIS DEVICE COMPLIES 
WITH P
A
R
T
 15 OF FCC R
U
LES
.
OPERA
TION IS SUBJECT 
T
O
 THE FOLLO
WING 
TW
O
CONDITIONS:
 (1) 
THIS DEVICE MA
Y NO
T CA
USE
HARMFUL INTERFERENCE, AND (2) 
THIS DEVICE MUST
A
CCEPT ANY INTERFERENCE RECEIVED
, INCLUDING
INTERFERENCE 
THA
T
 MA
Y CA
USE UNDESIRED
OPERA
TION.
THIS EQ
UIPMENT SHOULD BE INST
ALLED IN
A
CCORD
ANCE 
WITH 
THE NA
TIONAL FIRE PR
O
T
ECTION
ASSOCIA
TION ST
AND
ARDS ANSI/NFP
A 70 NA
T
ONAL
ELECTRIC CODE AND NFP
A
 72 NA
TIONAL FIRE ALARM
CODE, CHAPTER 2 (NA
TIONAL FIRE PR
O
TECTION ASSOC
.,
BA
TTER
YMARCH P
ARK, Q
U
INCY
, MA 02269).
 PRINTED
INFORMA
TION DESCRIBING PR
OPER INST
ALLA
TION,
EV
A
U
A
TION PLANNING AND REP
AIR SER
V
ICE IS 
T
O
 BE
PR
O
V
IDED WITH 
THIS 
EQ
UIPMENT
.
X10 ONL
CONNECTIONS
FCC ID:
 CFS8DLL
YNXREN-3
(L
YNXR-I) COMPLIES 
WITH
FCC R
ULES
, P
A
R
T
 68 FCC
REGISTRA
TION
No
. 5GB
USA-25623-AL-E
RINGER EQ
UIV
A
LENCE:
 0.6B
NO
TE
USE ONL
 THE K10145X10
CLASS 2
TRANSFORMERS
PR
O
VIDED
APX32EN SUMMAR
Y OF CONNECTIONS
THE APX32EN CONTR
OL IS COMP
A
T
IBLE 
WITH
THE FOLLO
WING INTEGRAL RECHARGEABLE
BA
TTER
Y P
A
CKS:
EXTERNAL SOUNDERS AND
PO
WERLINE CARRIER
DEVICES HA
VE NO
T BEEN
EV
ALU
A
TED BY UL.
FUTURE USE
REPLA
CE EVER
Y FOUR 
YEARS
P/N L
YNXRCHKIT
-SC
P/N L
YNXRCHKIT
-HC
P/N L
NXRCHKIT
-SHA
DA
T A
  IN
DA
T A
 OUT
*WHEN AVAILABLE
POWER
SHUTDOWN
NOTE:
AT
6.0
VDC
THE
SYSTEM
WILL
NOT
OPERA
TE
INCOMING
PHONE
LINE
TO
HANDSET
PHONE
LINE
W
ARNING:
T
O
 PREVENT RISK OF
SHOCK DISCONNECT
TELEPHONE LINE
A
T
 TELECOM 
J
A
CK
BEFORE SER
VICING
THIS UNIT
.
ALL OUTPUT CIRCUITS ARE PO
WER LIMITED
1
2
3
4
8
6
5
11
7
10
12
15
16
13
14
PHONE
FUTURE
USE
SOUNDERS
PLCD
AC
EAR
TH
GR
OUND
RING
TIP
RING
TIP
( )
( )
(+)
(+)
( )
D
ATA
OUT
SYNC
IN
RJ11
8
POS
JA
K
9
09012-012-V1
GND
LOCAL SOUNDER
DISABLE SHUNT
REMO
VE T
O
 DISABLE
UL NO
TE
THE MINIMUM 
WIRE SIZE USED FOR 
TELEPHONE
INST
ALLA
TIONS MUST BE #26 GA
UGE
SUPER HIGH-CAPACITY
BATTERY CONNECTOR
7845i-L
CONNECTIONS
PORT
GSMVL
COMMUNICATIONS
PORT
STANDARD
HIGH-CAPACITY
BATTERY CONNECTOR
UL INST
ALLA
TIONS
THE MINIMUM 
WIRE
SIZE USED FOR
TELEPHONE
INST
ALLA
TIONS
MUST BE #26 GA
UGE
 
Notes:  Connection of the fire alarm signal to a fire alarm headquarters or a central station shall be permitted with the 
approval of the local authority having jurisdiction. The burglar alarm signal shall not be connected to a police 
emergency number. 
 
 
The System must be checked by a qualified technician once every three years.