N. V. Nederlandsche Apparatenfabriek NEDAP ADRRFRFID User Manual

Page of 59
Page 
 of 
16
59
Manual iSense Lumen series
3.  However, the maximum cable length requirements needs to be satisfied. If it is not possible to put all
the gates within a role in one system due to the maximum cable length requirements, you can split the
gates into two or more systems. In this case assign each system a different 
 during
multi-system channel
the RF configuration.
Stock room to sales floor and goods receiving
For the stock room to sales floor and goods receiving roles: when there is a different door or
entrance, build a separate system.
Maximum system size
The table below shows the maximum system size for the diffent gates and tops in our product line
for different store positions.
Role / store position
Product
Max. system size
EAS 
RF Gates
100
Hybrid RF/RFID 30
RFID gates
30
RFID tops
30
Stockroom / Salesfloor
RFID gates
2
RFID tops
1
Goods receiving
RFID gates
2
RFID tops
1
It is not possible to combine gates with RFID and without RFID in one system. Either all gates should