Sigma Designs Inc ZM5304-U User Manual
Datasheet: ZM5304
12
DSH12461-3 | 7/2013
5
ELECTRICAL CHARACTERISTICS
This section describes the electrical parameters of the ZM5304 Modem module.
5.1 TEST CONDITIONS
Final Test in Production
(T
A
=+25°C, V
DD
=+3.3V)
Characterization in Lab
(T
A
=-10°C to +85°C, V
DD
=+2.3 to +3.6V)
Statistics with Min,
Typ, and Max values
Typ, and Max values
Sorting criterion
specified with Min and
Max values
Manufactured
Modules
Tested
Modules
Modules
Figure 5.1: Testing flow
The following conditions apply for characterization in the lab, unless otherwise noted.
1. Ambient temperature T
A
= -10 to +85°C
2. Supply voltage V
DD
= +2.3 to +3.6V
3. All tests are carried out on the ZDB5304 Z-Wave Development Board. [4]
4. Conducted transmission power is measured at the output of the SAW filter for 868.4, 908.4, 919.8, and 921.4MHz
5. Conducted receiver sensitivity is measure at the output of the SAW filter for 868.4, 908.4, 919.8, and 921.4MHz
4. Conducted transmission power is measured at the output of the SAW filter for 868.4, 908.4, 919.8, and 921.4MHz
5. Conducted receiver sensitivity is measure at the output of the SAW filter for 868.4, 908.4, 919.8, and 921.4MHz
The following conditions apply for the final test in production, unless otherwise noted.
1. Ambient temperature T
A
= +25°C
2. Supply voltage V
DD
= +3.3V
3. Radiated transmission power is measured for 868.4, 908.4, 919.8, and 921.4MHz
4. Radiated receiver sensitivity is measured for 868.4, 908.4, 919.8, and 921.4MHz
4. Radiated receiver sensitivity is measured for 868.4, 908.4, 919.8, and 921.4MHz
5.1.1 TYPICAL VALUES
Unless otherwise specified, typical data refer to the mean of a data set measured at an ambient temperature of T
A
=25°C and
supply voltage of V
DD
=+3.3V.
5.1.2 MINIMUM AND MAXIMUM VALUES
Unless otherwise specified the minimum and maximum values are guaranteed in the worst conditions of ambient temperature,
supply voltage and frequencies by a final test in production on 100% of the devices at an ambient temperature of T
supply voltage and frequencies by a final test in production on 100% of the devices at an ambient temperature of T
A
=25°C and
supply voltage of V
DD
=+3.3V.
For data based on measurements, the minimum and maximum values represent the mean value plus or minus three times the
standard deviation (µ±3σ).
standard deviation (µ±3σ).