Diagnosing Faults
Product Release 1
DOCNUMBER 9500
Document Issue 1.1
Page 8–6
February 2010
88
8
Fault code 5
Description
Vp under voltage.
Explanation
The mains board monitors the plate voltage (HV, Vp) for approximately 
2 seconds after the amplifier is turned fully on (ON 2).
If Vp fails to reach approximately 2.8 kV during this time, the mains 
board reports this fault code.
Resolution
1. Ensure that the mains board is selecting the correct primary 
transformer tap. See fault code 2 for information on how to do this.
2. If the correct primary tap is being selected, then the problem is 
elsewhere. Unplug the amplifier, remove the top cover, and inspect 
the mains board and high voltage board. Unplug each of the 
transformer connectors and inspect them for problems.
Fault code 6
Description
Output relay closure fail.
Explanation
The master controller monitors the state of the output relay using an 
auxiliary DC bias applied through a pair of RF chokes. This allows it to 
determine that the output relay has traveled to the closed condition, and 
that it is safe to bias the tube to OPERATE mode.
Resolution
Call RF Concepts at 303-473-9232.
Fault code 7
Description
Output relay may be stuck.
Explanation
If the output relay appears to be closed when the amplifier is keyed up, it 
is possible that the output relay is stuck in the ÖN condition for one of 
several reasons. See Fault code 6 for more information.
Resolution
None. You should not see this fault in the field.
Fault code 8
Description
Bandswitch set failure.
Explanation
The stepper motor controller processor is unable to land the apparent 
bandswitch position on the correct setting within the precision required.
Resolution
1. Turn the amplifier off and back on.