Nokia of America Corporation BBTRX-18 User Manual

Page of 61
Installing the AC power cable
There are two possible options while installing the AC power cable - using a connector or
hardwire the power cord.
Perform the following steps if your using a connector:
...................................................................................................................................................................................................
1
To terminate the unterminated end of the AC power cable, ensure that the plug used is
suitable to the environment of use. For example, in an uncontrolled outdoor environment,
use a waterproof plug that supports the supply voltage (120-V AC, 208-V AC, or 240-V
AC).
The cable may be cut down to length if the provided length of 14.7 ft (4.5 m) is more than
required. The plug must be provided by the customer.
...................................................................................................................................................................................................
2
Do not connect the far end of the power cord to the AC receptacle outlet or any other
power source until it is ready to turn on the 9768 MRO B4.
Hardwiring the power cord
Perform the following steps to hardwire the power cord:
...................................................................................................................................................................................................
1
The AC power cord is 14.7 ft (4.5 m) long. Locate the AC junction box within reach of
the AC power cord.
Ensure suitable drip loops can be maintained at, both, the 9768 MRO B4 and the junction
box.
...................................................................................................................................................................................................
2
Route the AC power from the source to the junction box per acceptable local codes.
...................................................................................................................................................................................................
3
Hardwire the power cord to the power source. If a local disconnect switch or circuit
breaker is desired, install one in the junction box.
Installing an 9768 MRO B4
Procedure 3-1: Installing the 9768 MRO B4 onto a wall or
pole
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9768 MRO
3MN-MRO-AWS-IMOP
Issue 1
February 2014
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
3-19