UTC Fire & Security Americas Corporation Inc 5INTWTTS User Manual

Page of 7
 
P/N 466-
5412 (EN) • REV A • ISS 17JAN18 
 
3 / 7 
The touch screen will indicate enrollment success or 
failure. 
Note: 
During install mode, it is normal for the four blue 
LEDs on the panel to blink as this indicates the panel is 
updating the touch screen status. Do not leave program 
mode if you have modified sensor information or are 
downloading a company logo while the four blue arming 
LEDs on the panel are blinking (this may disrupt 
configuration). 
9.  To verify that the touch screen is programmed (learned), 
press the Status button on the panel repeatedly to leave 
system programming and return to normal panel 
operation. 
10.  Press the Settings button on the touch screen and press 
the Hear button. 
The touch screen should announce the panel arming level 
and status, such as Disarmed System Okay
To program (learn) the touch screen into the Simon XTi 
and XTi-5 panel: 
1.  On the Simon XTi panel, press the 
 icon in the bottom 
right corner of the touchscreen. 
2.  From the Status & Settings screen, press 
 to scroll to 
the Programming option and press ENTER. 
3.  Enter the dealer or installer code and press OK. 
4.  From the Programming screen, press SENSORS. 
5.  From the Sensors screen, press LEARN SENSORS. The 
panel displays the Edit Sensor screen. 
On the touch screen: 
A.  Press the Settings button (gear icon at bottom right). 
B.  Press the Down arrow until the Clear and Enroll 
button appears. 
C.  Press the Clear and Enroll button. The touch screen 
should indicate it is waiting for enrollment. 
6.  On the panel, you can now program the group number 
(00, 01, 04, 05, 06, or 07) by pressing EDIT next to Sensor 
Group. 
7.  On the panel, select a name for the touch screen by 
pressing EDIT next to Sensor Name.  
You can select something simple, such as “Touch Pad”, or 
use additiona
l descriptors, such as “Bedroom Touch Pad”. 
The touch screen will indicate enrollment success or 
failure. 
Note: 
Do not leave program mode if you have modified 
sensor information or are downloading a company logo 
(this may disrupt configuration). 
8.  To verify that the touch screen is programmed (learned), 
press the Close button on the panel repeatedly to leave 
system programming and return to normal panel 
operation. 
9.  Press the Settings button on the touch screen and press 
the Listen button. 
The touch screen should announce the panel arming level 
and status, such as Disarmed System Okay
Refer to your Simon XTi or XTi-5 panel documentation for 
other programming options. 
Note: 
If you would like this touch screen operation to be code 
protected, you can enable this feature by following these steps: 
1.  Select the Settings menu. 
2. 
Scroll to “Code Required Access” and select Yes. 
With code required access, not all icons will be displayed. 
Relocate the touch screen to permanent location 
1.  Unplug the touch screen from the wall.  
2.  Move the unit to its permanent location.  
3.  Plug the touch screen power supply into the wall. 
Sensor test 
The touch screen is sensitive to its orientation to the control 
panel. For that reason, we recommend you test the touch 
screen before 
it’s mounted in its permanent location. 
To test the touch screen with the Simon XT (v1.4) panel: 
In the Setting menu, press the Test button under RF Test. If 
less than three bars appear 
see “Relocate the touch screen to 
permanent location
” above. 
To test the touch screen with the Simon XT (v1.3) panel: 
1.  Make sure the panel is disarmed. 
2.  Press the down arrow button on the panel and scroll to 
System Programming. 
3.  Press OK. 
4.  When the panel displays Enter Code, enter the 
appropriate code and press OK. 
5.  Scroll until the panel displays Sensor Test, press OK to 
start the sensor test. 
The panel will prompt you to trip each sensor one at a 
time. 
6.  To trip the touch screen, press the RF test button from the 
settings screen.  
You can follow the panel voice prompting to test the 
sensors in any order. You should hear the panel beep the 
number of packets received. The panel will also display 
the number of packets received. If you do not hear 6 to 8 
panel beeps, see “Relocate the touch screen to 
permanent location
” above. 
To test the touch screen with the Simon XTi and XTi-5 
panel: 
1.  Make sure the panel is disarmed.