UTC Fire & Security Americas Corporation Inc 788C-PIR User Manual

Page of 4
3
Installing Batteries and Setting up the
Transmitter
The detector contains a built-in transmitter that is used in
conjunction with a compatible receiver.  Use the following
instructions to set up the transmitter for wireless operation:
1. Make sure the tamper switch on PIR is released (not pressed
down), by removing the PIR from the wall mounting bracket.
2. Observing the proper polarity,  insert  lithium batteries
provided into the battery holder.
Important:
 
Once the batteries are installed, allow 3 minutes
for the detector to become fully operational before performing
walk testing.
3. Detach one of the device address labels from the transmitter
board and use it to enroll the detector at the control panel. See
the control panel manufacturer's instructions.
4. Walk test the detector to ensure proper operation and
coverage. See Walk Testing the Detector.
Walk Testing the Detector
The detector provides a Walktest mode for testing the detector
operation and coverage pattern.  Use the following instructions to
walk test the detector:
1. Remove the sensor from the bracket to enable the
Walktest mode.
2. When the sensor is remounted on the bracket, the detector
remains in the Walktest mode for 3-4 minutes.  Depending on
jumper settings, the Walktest mode allows the detector to alarm
whenever one or two curtain areas are entered. The LED visible
on the front cover lights to indicate an alarm.
Pet Alley Application
To create a detection free area close to the floor, mount the
detector about 3.5 feet above the floor, upside down (detector
window towards the ceiling). To reduce the exposure to the
ceiling, leave the plastic undercrawl mask in place.
As shown in Figure 7, pets are free to roam below the mounting
height of the detector without causing alarms.
3. Walk test the detection pattern, remove the sensor, and make
any necessary adjustments.
4. Replace the sensor, walk test the unit and verify the detector is
communicating with the control panel. Replace the securing
screw.  See the control panel manufacturer’s instructions.
Important:
 
After Walktest mode times out  (3 to 4 minutes), the
detector returns to normal operating mode. In normal operating
mode, the detector will alarm no more often than once every 3
minutes, and the LED is disabled to reduce battery consumption.
Maintaining the Detector
When installed and used properly, the AP950W provides up to 10
years of service with minimal maintenance. To ensure proper
operation, you should walk test the detector annually as described
in Walk Testing the Detector.
Clean the inside of the detector with a soft bristled brush or
compressed air. Clean the cover with a damp (water) cloth as
needed to keep it free of dust and dirt. Always test the detector
after cleaning.
Figure 7
Replacing the Batteries
Important: 
You must remove all  batteries to reset the low
battery signal before installing new batteries.
To ensure proper operation, if any battery is less than 3VDC,
replace all batteries.
Use only 3 V lithium CR-123A batteries as listed on the inside of
the detector.
Use of any other batteries may present a risk of fire or explosion.
Dispose of used batteries promptly.  Keep away from children.
Caution: 
Risk of fire, explosion, and burns. Do not recharge,
disassemble, heat above 212°F (100°C), or incinerate.  Dispose of
used batteries properly.