UTC Fire & Security Americas Corporation Inc 809B-SIREN User Manual

Page of 2
1
RF 2-Way Siren/Relay
ITI Part No. 60-xxx
Installation Instructions
Document Number: 466-1952 Rev. A PRELIMINARY
February 2002
Preliminary 2/8/02
Product Summary
The RF 2-Way Siren is a supervised device that transmits
supervisory signals for the panel to receive. When the bat-
tery is low, the module transmits a low battery signal.
Note
The RF 2-Way Siren does not have a backup power sup-
ply. Therefore, the battery must be replaced immediately
when a low battery condition occurs. If the battery is
allowed to completely drain, the panel identifies the RF 2-
Way Siren as being in a supervisory (non-working) state,
which prevents system events from being reported.
Installation Guidelines
Use the following guidelines when installing the RF 2-Way
Siren:
Before permanently mounting to a wall, test the RF 2-
Way Siren from the desired location to ensure commu-
nication to and from the panel. This means you must
first add (learn) the RF 2-Way Siren into panel mem-
ory. Then perform a sensor test.
Mount the module within 100 feet of the panel, but not
closer than 10 feet to another RF 2-Way Siren or the
panel.
Always mount the RF 2-Way Siren in the upright verti-
cal position.
Tools and Supplies
Phillips screwdriver
Two #6 phillips-head screws (included)
Two wall anchors (included)
Pencil
Installation
This section describes programming, testing, mounting, and
phone line connections.
Programming
This section describes the steps for adding (learning) the RF
2-Way Siren into panel memory.
1.
With the system disarmed, enter program mode by
pressing
+
.
2.
Press
twice and
twice. The display shows
ZONE
 
01 - 
TRIP
.
3.
Press Test button. The siren will beep three times, indi-
cating it is learned into the panel.
4.
Exit Program mode.
Testing
This section describes the basic steps for testing transmit-
ting reange from the RF 2-Way Siren to the panel. For com-
plete testing instructions, see the panel installation
instructions.
Note
Be sure to attach the cover to the RF 2-Way Siren before
testing communications.
1.
Straighten the antenna to a vertical position.
2.
Place the RF 2-Way Siren in the desired location.
3.
Enter sensor test mode on the panel
4.
Press Test button on siren.
5.
Listen for the panel piezo to sound 7 - 8 beeps. This
indicates good reception from the siren to the panel.
6.
If you hear fewer than 7 beeps, test the siren in different
locations. Mounting locations should be limited to
areas where the panel responds with 7 - 8 beeps.
7.
To re-test transmitting range after relocating the siren,
press the Test button again and listen for 7 - 8 beeps.
8.
Exit from the test mode after determining acceptable
locations.
Mounting and Antenna Positioning
After finding an acceptable mounting location (based on
testing), mount the RF 2-Way Siren and position the
antenna as described below. The antenna can be inserted
into a wall or positioned upright inside the antenna housing.
Note
For best range, it is recommended that the antenna be
inserted into the wall.
Mounting with Antenna in Wall
1.
Remove the circuit board from the plastic housing by
pushing up on the tab and pulling the board outward
(see Figure x). Place the board in the cover.
2.
Mark the mounting holes and the antenna insertion hole
(see Figure x).
WARNING: You must be free of all static
electricity when handling electronic compo-
nents. Touch a bare metal surface or wear a
grounding strap before touching the circuit.