UTC Fire & Security Americas Corporation Inc 944E-3G User Manual

Page of 4
 
Advisor Cellular Modem Installation Sheet 
 
3 / 4 
Module Configuration and Programming 
Module Configuration 
A CELLULAR module with a provisioned SIMM card will automatically configure to the Advisor panel and external service when the 
panel is powered up and a cellular connection is made. (No additional action is required, follow the steps below to verify the 
installation.)   
For un-provisioned module configuration, refer to the AdvisorOne Install and Programming manual (P/N 466-4405) for additional 
information. 
To Verify the CELLULAR Modem is Present and Configured Correctly: 
1.  Press        on the Main screen. 
2.  Press CONFIGURATION to enter module configuration and programming. 
3.  Enter the installer code, press CONTINUE
4.  From the main Options screen, press COMMUNICATION, then press INTERFACES
5.  Press EDIT next to CELLULAR Module.  
Ensure “Ready” is displayed.  If it is not and an error message is displayed, refer to the 
“Troubleshooting” section of this guide. 
Programming 
The CELLULAR module can be programmed for the following: reporting, two-way voice, remote maintenance (downloader), firmware 
management, and remote access (Smartphone).  Refer to the AdvisorOne Install and Programming manual (P/N 466-4405) for more 
information. 
If the module doe
sn’t automatically configure, see “Troubleshooting”. 
Troubleshooting 
 
Error 
Description 
SIMM error 
Verify SIMM card is in place and positioned correctly. 
PIN error 
Contact Technical Support. 
Signal strength is low 
• Ensure an antenna is present and connected properly. 
• Re-orient the antenna or change the panel location. 
• Contact Interlogix for other antenna options. 
If more information is required, refer to the AdvisorOne Install and Programming Manual (P/N 466-4405) or contact Technical Support. 
Specifications 
Compatibility 
Advisor Panel 
Storage temperature 
-29 to 140ºF (-34 to 60ºC)  
Operating temperature 
32 to 120ºF (0 to 49ºC) 
Maximum humidity 
85% relative humidity, noncondensing 
Regulatory Information 
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. 
These limits are designed to provide reasonable protection against harmful interference in a residential installation.  
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the 
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur 
in a particular installation.  
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment 
off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  
• 
Reorient or relocate the receiving antenna.  
• 
Increase the separation between the equipment and receiver.