UTC Fire & Security Americas Corporation Inc 958-BTWI User Manual
2 / 6
AdvisorOne Bluetooth WiFi Module Installation Sheet
CAUTION: Use static electricity precautions when handling electronic components.
4. Disconnect the battery from the battery connector (E in Figure 2) by pressing down on the wire end of the battery clip.
5. Remove the Communication Modules Cover by pulling outward on the tabs (F in Figure 2) and then lifting upward when tabs
release.
6. To access the location of the Bluetooth Wi-Fi module, remove the System Electronics Cover (this is the cover with a printed
wiring diagram) by pulling outward on the tabs (C in Figure 2), then disengaging the latch (D in Figure 2) with a small
screwdriver and lifting the cover upward when the latch releases.
screwdriver and lifting the cover upward when the latch releases.
Installing the Bluetooth Wi-Fi Module
1. Install the Bluetooth Wi-Fi module (A in Figures 1 and 3) into the Bluetooth Wi-Fi module location (with the bar code label side
up). Carefully align the header of the module (B in Figures 1 and 3) with the pins on the main circuit board. Press into place.
Note: The Bluetooth Wi-Fi module must be installed on the main board in the Bluetooth Wi-Fi location (A in Figure 3). DO NOT
force the module into place.
force the module into place.
2. Reinstall the System Electronics Cover, making sure the tabs (C in Figure 2) and the latch (D in Figure 2) are engaged.
3
Reinstall the Communication Modules Cover by pressing the cover down until the tabs (F in Figure 2) snap into place.
Note: All three internal covers must be secured for proper operation.
4. Supply power to the panel as noted in Table 2.
Table 1: Powering the Panel
Installation
Action
Note
US
Plug the power supply into the outlet and secure with the supplied screw.
Canada
Plug the power supply into the outlet.
Do not use the securement tab and screw.
All Other Installations
Follow regional requirements.
Note: Connect the battery within 15 seconds of providing AC power to reduce the potential for a low battery indication.
5. Connect the battery to the battery connector on the panel (E in Figure 2).
Note: The cable connector locks into place.
6
Close the panel, making sure all tabs are engaged. Replace the screw securing the panel chassis.
7. If the central monitoring station was notified, inform them this operation is complete.
Module Configuration and Programming
Module Configuration
– Wi-Fi Capability
1. Press the Settings icon on the lower left of the AdvisorOne main screen.
2. Press CONFIGURATION to enter programming. Enter installer or dealer code.
3. From the Configuration & Programming screen, press COMMUNICATION.
4. From the Communication screen, press INTERFACES.
For Wireless WAN
5a. From the Interface Communication screen, for press EDIT next to Wireless WAN. The following is displayed:
Table 2: Wi-Fi Wireless WAN Options
Option
Description
Name
Change the name of the Wi-Fi WAN interface. Optional, not recommended.
Line Fault
Sets the condition that if Wi-Fi connection fails, if the panel treats the loss as a fault or ignores it.
Recommended to leave as Off (default) unless high security monitoring of Wi-Fi link is needed.
Recommended to leave as Off (default) unless high security monitoring of Wi-Fi link is needed.
Wi-Fi Client
Configuration
This setting enables a Wi-Fi connection from the panel to a router for WAN access. Enabling this
selection will cause the SSID and credential information for a network to join to be accessible.