UTC Fire & Security Americas Corporation Inc 958-BTWI User Manual

Page of 6
2 / 6 
 
AdvisorOne Bluetooth WiFi Module Installation Sheet  
CAUTION: Use static electricity precautions when handling electronic components.  
4.  Disconnect the battery from the battery connector (E in Figure 2) by pressing down on the wire end of the battery clip. 
5.  Remove the Communication Modules Cover by pulling outward on the tabs (F in Figure 2) and then lifting upward when tabs 
release. 
6.  To access the location of the Bluetooth Wi-Fi module, remove the System Electronics Cover (this is the cover with a printed 
wiring diagram) by pulling outward on the tabs (C in Figure 2), then disengaging the latch (D in Figure 2) with a small 
screwdriver and lifting the cover upward when the latch releases. 
Installing the Bluetooth Wi-Fi Module 
1.  Install the Bluetooth Wi-Fi module (A in Figures 1 and 3) into the Bluetooth Wi-Fi module location (with the bar code label side 
up). Carefully align the header of the module (B in Figures 1 and 3) with the pins on the main circuit board. Press into place. 
Note: The Bluetooth Wi-Fi module must be installed on the main board in the Bluetooth Wi-Fi location (A in Figure 3). DO NOT 
force the module into place. 
2.  Reinstall the System Electronics Cover, making sure the tabs (C in Figure 2) and the latch (D in Figure 2) are engaged. 
Reinstall the Communication Modules Cover by pressing the cover down until the tabs (F in Figure 2) snap into place. 
 
Note: All three internal covers must be secured for proper operation. 
4.   Supply power to the panel as noted in Table 2. 
Table 1: Powering the Panel 
Installation 
Action 
Note 
US 
Plug the power supply into the outlet and secure with the supplied screw. 
 
Canada 
Plug the power supply into the outlet. 
Do not use the securement tab and screw. 
All Other Installations  
Follow regional requirements. 
 
Note: Connect the battery within 15 seconds of providing AC power to reduce the potential for a low battery indication. 
5.  Connect the battery to the battery connector on the panel (E in Figure 2).  
Note: The cable connector locks into place. 
Close the panel, making sure all tabs are engaged. Replace the screw securing the panel chassis. 
7.  If the central monitoring station was notified, inform them this operation is complete. 
Module Configuration and Programming 
Module Configuration 
– Wi-Fi Capability 
1.  Press the Settings icon        on the lower left of the AdvisorOne main screen. 
2.  Press CONFIGURATION to enter programming. Enter installer or dealer code. 
3.  From the Configuration & Programming screen, press COMMUNICATION
4.  From the Communication screen, press INTERFACES
For Wireless WAN 
5a.  From the Interface Communication screen, for  press EDIT next to Wireless WAN.  The following is displayed: 
Table 2:  Wi-Fi Wireless WAN Options 
Option 
Description 
Name 
Change the name of the Wi-Fi WAN interface.  Optional, not recommended. 
Line Fault 
Sets the condition that if Wi-Fi connection fails, if the panel treats the loss as a fault or ignores it.   
Recommended to leave as Off (default) unless high security monitoring of Wi-Fi link is needed. 
Wi-Fi Client 
Configuration 
This setting enables a Wi-Fi connection from the panel to a router for WAN access.    Enabling this 
selection will cause the SSID and credential information for a network to join to be accessible.