UTC Fire & Security Americas Corporation Inc TX-1510-01 User Manual

Page of 2
DesignLine Recessed Door Contact
Installation Instructions
2
Enrolling
The following section describes general guidelines for program-
ming (learning) the sensor into the panel’s memory. Refer to you 
panel documentation for complete programming details.
To program (learn) the contact into the panel, do the following:
1.
Unscrew the top of the contact.
2.
Set the panel into program mode.
3.
Refer to your panel documentation for instructions for 
learning sensors.
4.
Press and release the tamper switch on the top of the contact 
circuit board (Figure 1 on page 1)until the panel responds.
5.
Replace the contact top.
6.
Exit program mode.
Specifications
Battery
CR2032, 3 VDC, 225 mAh, Lithium Coin Cell
Typical battery life
5 to 8 years
Transmitter frequency
319.508 MHz (crystal-controlled)
Transmitter frequency tolerance ± 8 kHz
Bandwidth
24 kHz
Modulation type
Amplitude shift key (ASK)
Unique ID codes
16 million
Peak field strength
Typical 35,000 uV/m at 3 m
Supervisory interval
64 minutes
Operating temperature
10  to 120°F (-12 to 49°C)
Enclosure
PC-540
Weight
0.63 oz. (18 g)
Dimensions (L x W x H)
1.70 x 1.10 x 0.91 in. (4.32 x 2.76 x 2.32 cm)
Color
Belgian gray
FCC
This device complies with part 15 of the FCC rules.  Operation is 
subject to the following conditions: 
1. This device may not cause harmful interference. 
2. This device must accept any interference received, including 
interference that may cause undesired operation. 
Changes or modifications not expressly approved by the party 
responsible for compliance could void the user’s authority to 
operate the equipment. 
FCC ID:  B4Z-TX-1510-01
Industry Canada ID: 1175C-TX151001 
EMC
European representative for manufacture (EMC): 
GE Security, Kelvinstraat 7, 6003 DH Weert, Nederland
The European directive Waste Electrical and Electronic Equipment 
(WEEE) aims to minimize the impact of electrical and electronic 
equipment waste on the environment and human health. For proper 
treatment, recovery, and recycling, return the equipment marked 
with this symbol to your local supplier upon the purchase of equiva-
lent new equipment, or dispose of it in designated collection points. 
For more information, visit 
Technical support
Toll-free:  888.GESECURity (888.437.3287) in the US, including Alaska and Hawaii; Puerto Rico; Canada. 
Outside the toll-free area:  Contact your local dealer.