13.3. Output-Contact 
Descriptions 
 
Output1:  This is a transistor output for heartbeat 
signalling. The heartbeat interval can be 
set in the 1-to-72-hours range.
 
 
 
Output2: This optocoupler output, which is signalling 
the operating condition, represents the same 
functionality as LED1. 
 
open 
power feed out of defined window 
 or 
LO-Alarm 
 or 
temperature-alarm 
close 
normal operation condition 
 
Output3:  This optocoupler output, which is signalling 
the ALC condition, represents the same 
functionality as LED2. 
 
 
open 
ALC-Alarm, ALC active 
close 
normal operation condition 
 
14. Heartbeat 
Setting 
 
In a remote monitoring system, heartbeat signalling is 
a very useful method to monitor whether the 
supervision connection to a device is still operational. 
Without heartbeat signalling, there would be no 
indication if the supervision connection failed.  
 
The heartbeat interval can be set by means of a rotary 
switch, which is accessible on the top of the 
miniRepeater. Use a small screwdriver to turn the 
switch carefully to the position for the required interval 
(1 to 72 hours) according to the label in the cover. 
 
not allowed
1  h 
24 h 
not allowed
2 h 
30 h 
3 h 
36 h 
4 h 
48 h 
5 h 
60 h 
6 h 
72 h 
8 12 
 
 
9 18 
 
 
Heartbeat-switch settings 
 
miniRepeater with cover 
 
 
15.  List of Changes 
 
Version Changes 
Release 
Date 
M0041AMA  
07-Feb.-06 
M0041AMB - Mikom GmbH 
changed its name 
into Andrew Wireless 
Systems GmbH 
- Chapter 1 changed 
- Chapter 5 changed 
- Chapter 7 changed 
21-Nov.-06 
 
 
Collector-emitter voltage......50 V max
Collector current..................20 mA max
Collector-emitter voltage......50 V max
Collector current..................20 mA max
output voltage.......4.75 to 5.25 
output current.......20 mA 
1kOhm
 
+5
Position of the rotary 
switch for setting of 
heartbeat interval