66.2.  Down link power levels: remote unit + booster  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
NUMBER OF 
CARRIERS 
(N) 
Max power per 
carrier at TFL DL RF 
input (a
P
IN TFL
 /carrier  
[dBm] 
Max power per 
carrier at TFA RF 
output (b
P
OUT TFA
 /carrier 
[dBm] 
Max power per 
carrier at TFB RF 
output (c
P
OUT TFB
 /carrier 
[dBm] 
1 0,0 
7,0  20,0 
2 -4,0 
3,0  16,0 
3 -6,3 
0,7  13,7 
4 -7,3  -0,3  12,7 
5 -8,2  -1,2  11,8 
6 -8,8  -1,8  11,2 
7 -9,3  -2,3  10,7 
8 -9,7  -2,7  10,3 
9 -10,1  -3,1 
9,9 
10 -10,4 
-3,4 
9,6 
11 -10,7 
-3,7 
9,3 
12 -11,0 
-4,0 
9,0 
14 -11,5 
-4,5 
8,5 
16 -11,9 
-4,9 
8,1 
18 -12,2 
-5,2 
7,8 
20 -12,6 
-5,6 
7,4 
22 -12,8 
-5,8 
7,2 
26 -13,3 
-6,3 
6,7 
30 -13,8 
-6,8 
6,2 
34 -14,1 
-7,1 
5,9 
40 -14,6 
-7,6 
5,4 
NOTES: 
DL power levels for Britecell 900 MHz + TFB915  
DL power levels for Britecell 1800 MHz + TFB1815 
 
The DL levels at Booster output assume that the cable connecting TFA and booster 
has  1 dB  loss.  
 
TFLxxxx4H-x
 
TFL DL RF 
input 
TFL UL RF 
output
 
b
 
TFBxxxx 
TFAxxxx