Andrew Wireless Innovations Group BCEL-FAST900 User Manual
MN021-01
Page 19 of 28
Figure 16 Optical Fiber Connection Examples
12.4.
Test point
An electrical test point is available on the remote unit to check the downlink optical power.
Connect the fibre coming from the local unit, power both units and measure with a multimeter
the voltage between ground and the test point. A satisfactory DL optical power will give
measurement greater than 300mV, corresponding to an optical power level of around –5dBm.
Connect the fibre coming from the local unit, power both units and measure with a multimeter
the voltage between ground and the test point. A satisfactory DL optical power will give
measurement greater than 300mV, corresponding to an optical power level of around –5dBm.
Figure 17 Remote Unit TFAF Electrical Test Point
13. Troubleshooting
REMOTE UNIT ALARM
Alarm LED STATUS SEVERITY
ACTION
DL AGC out of range
RED
Flashing
MINOR
Optical power below –4dBm:
check for fiber or splices
stresses, clean optical
connectors
check for fiber or splices
stresses, clean optical
connectors
DL optical power too low
RED
Fixed
MAJOR
Optical power below –6dBm:
check for fiber or splices
stresses, clean optical
connectors
check for fiber or splices
stresses, clean optical
connectors
DL RF amplifier 1
RED
Fixed
MAJOR
Internal failure: replace TFAF
DL RF amplifier 2
RED
Fixed
MAJOR
Internal failure: replace TFAF
Antenna disconnected (DC
loop)
loop)
RED
Flashing
MINOR
Antenna cable probably
broken or disconnected.
broken or disconnected.
Antenna connected to TFAF
doesn’t support DC-loopà see
store procedure to mask
unwanted alarm
doesn’t support DC-loopà see
store procedure to mask
unwanted alarm
External 1
RED
Fixed
MAJOR
External alarm 1
External 2
RED
Fixed
MAJOR
External alarm 2
WRONG OPTIMAL