Andrew Wireless Innovations Group MRB-LMR User Manual
4. Setting Up for Initial Operation
MR Booster Manual: (MN001808-1, 9/99)
Page 35
Basic steps to set up alarms in the repeater:
1. Set thresholds
2. Set alarm criticality
3. Set external I/O (optional)
2. Set alarm criticality
3. Set external I/O (optional)
Example
The following example shows how to set output relay one to open when PA
temperatures exceed +80C.
temperatures exceed +80C.
First, set the alarm threshold:
1. At the > prompt, type SET; press Enter.
2. From the menu prompt, type D; press Enter.
3. Type C; press Enter. (For Max PA Temp - Alarm Point)
4. Type 80; press Enter.
Second, set the alarm criticality:
5. Type E; press Enter. (For the Critical Alarms Menu)
Alarms
A Max Power Supply Temp - Alarm Point...+85 Deg C
B AC Power Fail - Alarm Point...........10.0 Minutes
C Max PA Temp - Alarm Point.............+90 Deg C
D External I/O..........................NORMAL STATES
E Critical Alarms.......................NO ALARMS REPORTED
Critical Alarms
A PA POWER HI ALARM.....................LOG ONLY
B PA POWER LO ALARM.....................LOG ONLY
C PA TEMP HI ALARM......................LOG ONLY
D PA OUT-OF-SERVICE ALARM...............LOG ONLY
E PA OVERCURRENT/OVERDRIVE ALARM........LOG ONLY
F POWER SUPPLY TEMP HI ALARM............LOG ONLY
G AC POWER LOST ALARM...................LOG ONLY
H POWER SUPPLY REGULATION ALARM.........LOG ONLY
I VSWR HI ALARM.........................LOG ONLY
B PA POWER LO ALARM.....................LOG ONLY
C PA TEMP HI ALARM......................LOG ONLY
D PA OUT-OF-SERVICE ALARM...............LOG ONLY
E PA OVERCURRENT/OVERDRIVE ALARM........LOG ONLY
F POWER SUPPLY TEMP HI ALARM............LOG ONLY
G AC POWER LOST ALARM...................LOG ONLY
H POWER SUPPLY REGULATION ALARM.........LOG ONLY
I VSWR HI ALARM.........................LOG ONLY