Andrew Wireless Innovations Group RPT-MMR8-19I User Manual

Page of 43
4 Installation
ID No: 159967
Page 17
4.  INSTALLATION
4.1. 
MECHANICAL INSTALLATION
4.1.1.  General
Read the health and safety warnings in chapter 1.2 Health and Safety Warnings.
1.  Do not install the unit in a way or at a place where the specifications
outlined in the Environmental and Safety Specifications leaflet of Mikom are
not met.
2.  It is strongly recommended to install the unit vertically with the fan unit at
the top. If a different installation of the remote unit is required, please
contact customer service for further information.
3.  It is recommended only to use the mounting hardware delivered by Mikom.
If different mounting hardware is used, the specifications for stationary use
of the remote unit must not be exceeded.
F
 Note:
Exceeding the specified load limits may cause the loss of warranty!
4. 
  The unit is considerably heavy. Make sure that a suitable mounting
surface is used. Ensure there is adequate manpower to handle the weight of
the system.
5.  Due to power dissipation, the remote unit may reach a very high
temperature. Ensure sufficient airflow for ventilation as specified in the
individual mounting procedures.
If any different or additional mounting material is used, ensure that the mounting
remains as safe as the mounting designed by Mikom. Ensure that the static and
dynamic strengths are adequate for the environmental conditions of the site. The
mounting itself must not vibrate, swing or move in any way that might cause damage
to the remote unit.
Specified torques have to be observed for certain mounting procedures according to
the following table:
Type
Tallow-drop
screws
Hex
nuts
Spacing bolts
PG
(plastic)
PG
(aluminium)
Thread
M 4
M 8
M 4
M 8
PG 13,5
PG 29
Specified
torques
3.3 Nm
27 Nm
2.3 Nm 27 Nm
3.75 Nm 10 Nm
table 4-1 Specified torques