4.1.3.  Outside Pole Mounting Procedure
Standard mounting hardware can not be used to mount the remote unit to a pole, a
column or other similar structures. Additional hardware must be used for this type of
installation. Such a pole mounting kit could include two threaded rods M8, two U-
beams and mounting material like bolts and nuts.
F
 Note:
To ensure sufficient airflow a distance of at least 50mm has to be
observed. Do not block the airflow by installing other devices at a
nearer distance to the unit.
figure 4-3 Pole mounting kit
  Use the screw bands to fasten the two U-beams to the pole as illustrated in figure
4-4 Pole mounting.
F
 Note:
When fastening the U-beams make sure that they are installed
congruently and not at an angle to each other. To determine the
distance between the beams refer to  figure 4-2 Wall mounting
 for