4 Installation
ID No: 159967
Page 23
figure 4-6 Mounting aid brackets
  Carry out all connection procedures at the connector flange described in chapter
4.2 Electrical Installation.
  Put four of the M8 washers DIN9021 over the spacing bolts inside the pole.
  Lead the unit inside the opening of the pole by pulling the ratchet downwards and
detach the unit from the mounting studs of the ratchet to insert it completely into
the pole fitting the mounting drillings on top and bottom onto the four spacing
bolts (M8 thread) inside the pole.
  Push the unit in completely till it hits the backstop. Since the drillings are
somewhat higher than the spacing bolts the vertical position of the unit is slightly
adjustable. Then, put the remaining M8 washers DIN9021 over the spacing bolts.
  Fasten the unit with the washers to the spacing bolts using appropriate tools and
material.
F
 Note:
To ensure  sufficient airflow, two lid openings (one for the air inlet
and the other for the air outlet) with a size of at least 144 cm² have
to be provided. Also, make sure there is no thermal short circuit
between the air inlet and air outlet.