5 Commissioning
ID No: 159967
Page 31
5.  COMMISSIONING
5.1. 
GENERAL
Read the health and safety warnings in chapter  1.2  Health and Safety Warnings as
well as the description carefully to avoid mistakes and proceed step by step as
described!
Ø 
Do not operate the remote unit without termination of the antenna connections!
The termination can be achieved by connecting the antennas, a dummy load
or the 50-Ohm-terminated connection of a measuring instrument.
Ø 
To ensure safety, the electrical and subsequent installations, commissioning
and maintenance activities that require the unit to be under power while open,
must only be carried out by suitably qualified personnel.
Ø 
When opening the remote unit, do not damage the seals on the devices inside
the remote unit. Warranty void if the seals are broken!
Ø 
To query the status, the remote unit can be accessed remotely via a master
unit.
Ø 
Since the system provides an auto-levelling and auto-setup function, no further
settings are necessary at the remote unit itself. All other settings are required
at the master unit and are explained in the corresponding documentation.
5.2. 
AUTO-LEVELLING
In order for the auto-levelling function to operate properly, a defined level has to be
set at the optical interface (DL) of the master unit. For details refer to the description
of the master unit.
5.3. 
REMOTE OPERATION
For details refer to the descriptions of the master unit and corresponding software.