7.2 Setting of operational parameters
Attenuation of the Repeater can be set manually, locally or remotely. Frequency can be set
locally and remotely.
There are three different possibilities to set the operational parameters:
-manual settings by means of rotary switches
-local control via RS232 interface and PC
-remote control via Master Unit
7.2.1 Manual setting of the attenuation by means of rotary switches
The manual mode allows the user to set the required attenuation by means of rotary switches.
With a small screwdriver, which fits through the long holes of the RF modules, the values can
be adjusted by turning the switch carefully to the desired position.
Note:
To enable manual settings of parameters the mode switch (DIP-Switch 1)
has to be changed from OFF to ON.
The DIP-Switch is mounted on the control module, located on the left-hand side of the
Repeater.
figure 7-2 Position of the DIP-Switch 1
DIP-Switch 1