Andrew Wireless Innovations Group RPT-MOR701 User Manual

Page of 79
User’s manual for Remote Unit MOR701B Power
M0069A0A.doc
Id.-No 151154
Page 68
23-June-99
figure 9-15 Position of the feed forward amplifier reset board
Remove the ready made cable which is plugged to the 15 pole SUB-D connector of the reset
board. Unscrew the screw clip first.
The SMA connectors can be removed only after dismounting the amplifier.
Position of the feed forward amplifier is illustrated in figure 9-16 Position of feed forward
amplifier (Right-hand side of Repeater).
figure 9-16 Position of feed forward amplifier (Right-hand side of Repeater)
Reset board
feed
forward
amplifier