Andrew Wireless Innovations Group RPT-MOR801 User Manual

Page of 79
User’s manual for Remote Unit MOR801B Power
M0070A0A.doc
Id.-No 151155
Page 28
18-June-99
NO.
ALARM NAME
ALARM ACTIVE STATUS
1
AMPLIFIER  BIAS
FAILURE
2
POWER SUPPLY 8 V
FAILURE
3
POWER SUPPLY 12 V
FAILURE
4
MAINS
FAILURE
5
SYNTH
FAILURE
6
DOOR
OPEN
(7)
VSWR
ALARM
8
ALC
FAILURE
9
LITHIUM BATTERY VOLTAGE
LOW
10
OVERTEMP
11
INVALID LOGIN ATTEMPT
12
I2C BUS
FAILURE
(13*)
EXT. ALARM 1
FAILURE
(14*)
EXT. ALARM 2
FAILURE
(15*)
EXT. ALARM 3
FAILURE
(16*)
EXT. ALARM 4
FAILURE
(17**)
EXT. BATTERY
OVERTEMP.
Alarm default settings changeable by software instruction SET ALIAS.
** 
This alarm may be activated together with the external alarms, for instance UPS
temperature
(...)
Optional alarms
table 3-4 List of all available alarms
3.4.1
 
Handling of alarms
As soon as the software recognizes a valid alarm, a message is transmitted to theMaster Unit.
If the reason for the alarm has been cleared or if the alarm should continue, a new alarm
message will not be repeated. If there was an interruption of at least one second after
acknowledgement, a new alarm message will be generated.