9.13  Replacement of the FSK modulator
To remove the FSK modulator disconnect all connected cables. Remove the two tallow drop
screws which connect the FSK modulator with the MFY1309. The device can be removed.
figure 9-17 FSK modulator
9.14  Replacement of the Transceiver MFY1309
To remove the Transceiver dismount the FSK modulator which is fixed with two screws M3
on top of the Transceiver. Disconnect all cables. Then unscrew the four counter sunk screws
M3 at the connector panel. Now you can remove the Transceiver MFY1309.
figure 9-18 Installation position
Transceiver MFY
FSK modulator