Andrew Wireless Innovations Group RPT-MR701 User Manual

Page of 76
User’s manual for Repeater MR801B Power
M0067A0A.doc
Id.-No 151111
Page 45
02-JUNE-99
6.2.2 Power connection
Before connecting electrical power to the Repeater grounding has to be performed. The
Repeater is equipped with a firmly connected power cord 3 x 1.5 mm². Due to safety reasons
the power supply lead of the Repeater has to be protected with two 8 A fuses, type MT. In the
event the length of the power cord should not be sufficient it can be replaced by a longer
cable.
figure 6-5 Screw terminal
Note:
If the power supply lead has to be replaced use a cable of the same quality.
6.2.3 Connection of the antenna cables
The Repeater has two female antenna connectors 7/16. For mounting the corresponding cable
connectors we recommend to refer to the applicable documentation of the respective
connector manufacturer. The bending radius of the antenna cables must remain within its
specification. This will warrant proper operation of the system; otherwise changes in the
electrical behaviour of the cable might occur which could cause malfunction of the Repeater
system.
Note: 
It is sufficient to fix the 7/16 antenna connectors hand-screwed.
Any use of a tool (like tongs) might cause damage to the connectors and
thus lead to malfunctioning of the Repeater.