Andrew Wireless Innovations Group RPT-MR703 User Manual

Page of 1
Appendix A : Installation Checklist:MR703D Users Guide Manual 149678 (m0041a3a, 6\00)
Page A-1
Appendix A : Installation Checklist
The following checklist provides a summary of the procedures for installing a MR703D system:
Step
Item/ Action
Description
1
MR703D Site Drawing
Master copy of the site plan noting the MR703D location and
serial number, and the location of the indoor coverage
antenna(s)).  This should characterize the design parameters
for the system including cable paths and lengths.
2
Equipme nt List:
Quantity:
 MR703D
 AC Power Outlet
 Coverage Antenna*
 Donor Antenna
 50-ohm Donor Antenna Cable
 50-ohm Donor Jumper*
 50-ohm Coverage Antenna Cable
3
Installation tools:
 Cable connector Tools*
Crimper, knife, etc.
 Multimeter
To ensure no cable shorts.
 Handset with Power Indicator
To verify coverage after commissioning.
4
Calculate RF Output Power (ERP) at
antennas for FCC RF exposure
compliance..
Installer must verify that the Output Power at the antennas is
less than 3W ERP, this must include cable loss and antenna
gain. For additional information, contact Mikom technical
support at (800)-800-7465
5
Run Cable
Install Cable in the site.
6
Attach Connectors*
Measure across center pin and outer shell (ground) to ensure
no short.
7
Verify  “Donor and
CoverageAntennas ” locations are
consistant with RF exposure warning
(see above and below).
Be sure to record the antennas location status for future
reference.
8
Record Serial Numbers and Locations
on site Drawing.
Note: this is to aid the Mikom Technical Support Specialists,
should you need their assistance.
9
Mount the Equipment
Including indoor coverage antennas for metal case models.
10
Connect the 50-ohm Cables as shown
on the Site Plan
Use caution when connecting semi-flexible cables to the
mounted MR703D and antennas.  Excessive force on antenna
or MR703D connectors will result in serious equipment
damage.
11
Supply AC Power, and commission
the System.
Check the MR703D status as described in previous section .
12
Check Power Levels
Check power indication of handheld mobile at various
locations within the coverage area.
As Required
WARNING INSTALLERS! This device must be installed so that while
this device is in operation, a separation distance of at least 20 centimeters
must be maintained between radiating antennas and the body of the user
or nearby persons in order to meet the FCC RF exposure guidelines.
WARNING INSTALLERS! This device must be installed so that while
this device is in operation, a separation distance of at least 20 centimeters
must be maintained between radiating antennas and the body of the user
or nearby persons in order to meet the FCC RF exposure guidelines.