Andrew Wireless Innovations Group RPT-MR703P User Manual

Page of 59
U
SER
´
S MANUAL FOR BAND SELECTIVE REPEATERS 
MR
X
03P 
 
 
User'sManual.doc 
Id.-No.:154999 
Page 15 
22-Jan-01 
 
2.3.5.  Control Module 
 
The control module is a DOS compatible micro computer. The whole communication 
between the provider and the repeater can be done via the control module. 
 
The repeater can be controlled remotely or locally via a VT100 terminal or a PC 
emulating the VT100 terminal. 
 
To control the repeater remotely, use either the RS232 interface in connection with a 
wireless modem or the PCMCIA interface in connection with a modem card and a 
mobile or PSTN network adapter. The RS232 interface and the PCMCIA interface 
are located on the control module. 
 
Frequency, gain, power down of RF stages and ALC can be controlled and status 
messages can be received remotely. In case a PSTN modem or a mobile is 
connected, automatic alarm messages can be received. 
 
The data transfer between the control module and the mother board is realized by 
the I
2
C-Bus system. 
 
The I
2
C-Bus concept was developed by Philips for the serial connection of integrated 
circuits within one device. Two wires, serial data (SDA) and serial clock (SCL), carry 
information between the devices connected to the bus. Each device is recognized by 
a unique address and can operate either as transmitter or receiver. 
 
All MRx03P configuration parameters are non-volatile stored in an EEPROM on the 
control module if power supply failure occurs. 
 
 
figure 2-5 Control module