7.2. 
BOOT PROCESS 
 
Following signals occur during boot process 
 
Internal 
LED LE1 
Internal 
LED LE2 
Internal  
LED LE3 
Status 
green 
red 
green 
red 
green 
 
l 
Power on state, Software 
boot starts 
l 
Flashes 
red short 
time 
l 
Flashes 
red 
short 
time 
l 
Software boot starts 
l 
 
l 
 
l 
Software is running 
 
The boot process takes about 3 minutes 
 
7.3. 
ALARM MONITORING WITH THE ALARM HISTORY 
 
Check the alarm history. 
 
1.  If a hardware module is damaged, replace corresponding hardware module. 
2.  Minor alarms with no influence on the system can be cancelled by confirming the 
alarm with the software command ‘alarmackn’, e.g., DOOR OPEN. 
3.  If all alarms have been acknowledged the summary error LEDs will be set back to 
green indication. 
4.  In case of mains power failure the contents of the actual alarm history list will be 
lost. 
 
List with all available alarms in the alarm history. 
 
 
7.4. 
POWER SUPPLY 
 
Factory set output voltages ( with load ) 
 
• 
  7.8 V ± 0.1 V 
• 
12.4 V ± 0.1 V 
 
In case of an I²C-Bus error, also check the power supplies. They must be switched to 
position ON.