Andrew Wireless Innovations Group RPT-MR703P User Manual

Page of 59
U
SER
´
S MANUAL FOR BAND SELECTIVE REPEATERS 
MR
X
03P 
 
 
User'sManual.doc 
Id.-No.:154999 
Page 45 
22-Jan-01 
 
Loose the mounting screw of cable gland at the outside of the heat sink (see  figure 
8-3 Cable gland) and pull the cable through the hole. 
 
For mounting a new mains cable proceed in reverse order. 
 
∗ Note 
The diameter of the power supply lead has to be in the range of  
9.5 mm max. and 6.5 mm min.
 
 
Strip the isolation of the cable to the length of 18 cm and pull it through the cable 
gland like depicted in 8.4. Inside the housing, use the insulated tube. 
 
 
figure 8-3 Cable gland 
8.4. 
REPLACEMENT OF THE RAM / RTC BATTERY 
 
The RAM/RTC battery of the control module has to be replaced in case of memory 
loss or as a preventive measure after approximately three years usage. The 
RAM/RTC battery is mounted underneath the battery backup module. It is accessible 
after opening the housing on the left-hand side in the lid. 
 
First remove the whole battery backup module (see chapter  8.5) which is plugged 
into the control module. By means of a small screwdriver, placed between the battery 
and the battery socket, the battery can be taken out of the battery socket. 
 
The type of the battery is CR 2450 Lithium 3V/500mAh, manufacturer is RENATA. 
 
After replacement of the RAM battery, the control module has its basic settings.