8.8. 
CONTROL MODULE SM 2009 
 
The control module is a Printed Circuit Board and is situated in the lid of the housing. 
 
Disconnect the DC cable from power supply. 
 
Disconnect flat cable. 
 
Remove the modem. 
 
Take off the whole control module completely with chassis by unscrewing four nuts 
M4 or the four knurled screws. 
 
For mounting proceed in reverse order. 
 
8.9. 
POWER SUPPLY 
 
∗ Note 
Ensure that mains are disconnected and the battery backup 
module is switched off.
 
 
The power supply is mounted in the lid of the housing. Open the repeater to get 
access to the device. 
 
Remove all connected cables from the clamps of the power supply. Remove the 
ground cable. 
 
The power supply is fastened to the lid of the housing by means of two nuts M4 on 
the right-hand side. After loosen the screws, the power supply can be removed. A 
special key with a mobile element will be required to open these screws. 
 
∗ Note 
Don’t forget to put heat conducting paste on the mounting side for  
installation of a new power supply. Use the conducting paste 
which is included in the spare parts kit.