2.5 Required software commands
The software command to set the centre frequency (CF1 and CF2) of the filters and the
attenuation is given in the following.
With the SET CF command the centre frequency of a filter can be set with an accuracy of 10
kHz in GSM900 and 100kHz in GSM1800. The SET CFO (centre frequency offset) command
is for correction purposes only and should be avoided if possible. SET CFO can be set in steps
of 10 kHz from – 1000 kHz to + 1000 kHz. (See also software manual for more details.)
SET CF
Syntax:
SET CF 
ENTER BAND MODULE (1-8): 
ENTER CF UL <MHz>: 
ENTER CF DL <MHz>: 
SET CFO
Syntax:
SET CFO 
ENTER BAND MODULE (1-8): 
ENTER CFO UL <kHz>: 
ENTER CFO DL <kHz>: 
SET ATT
Syntax:
(ENTER Repeater Number (1-4): 
)  *
ENTER BAND MODULE ( 1-8 ): 
ENTER MODE ( UL or DL): 
ENTER ATTENUATION: 
* (This is only valid in some earlier software versions!)
Band module number can be found in table “Band module number”.