Andrew Wireless Innovations Group 9GB2000 User Manual

Page of 339
 
Any combination of 19-2000-1 IS-136 RF modules and 19-5599-1
Cellular I.F. modules may be placed in the remaining slots in the card
cage.
1.1.3  45W PA Module
The 1819.G1 class AB linear PA must be used with the 19-20000-1 module.  The
class C PAs (21-117-1, 21-396-1, etc.) are usable only with the analog 19-5599-1
Cellular I.F. modules.  Note also that the 1819.G1 linear PA cannot be used in
place of a class C PA.  No power output will be provided in either case if the PA
is mismatched with its corresponding RF module.
Note that the 1819.G1 PA, the 19-20000-1 and the 19-20001-1 modules have
reverse-colored labels (white on blue instead of blue on white) to provide a quick
visual aid in identifying the modules required for TIA-136 operation.  The
1819.G1 PA also has a label on its handle stating that it is an “IS-136 Linear PA”.
It is also white-on-blue to match the corresponding controller and RF module
labels.
1.2 Kit Contents
To allow field conversion of EAC-2000 installations to digital operation, two kits are
available:
If the EAC-2000 has a 19-5598-1 Controller module installed, then a EK2000DCCH
kit must be ordered.  The EK2000ACCH kit consists of:
  One 19-20001-1 Controller Module
  One 19-20000-1 IS-136 RF Module
  One 1819.G1 IS-136 Linear PA
If the EAC-2000 has a 19-20001-1 Controller module installed, then an
EK2000DTC kit must be ordered.   EK2000DTC kit consists of:
  One 19-20000-1 IS-136 RF Module
  One 1819.G1 IS-136 Linear PA
The EK2000DTC kit may be used for the DCCH channel if the EAC-2000 already
has the 19-20001-1 Controller Module installed.  Otherwise, any number of
EK2000DTC kits may be ordered to add or increase DTC capacity in the EAC-2000.
Any shortage or apparent damage should be resolved before beginning the
installation.