Eaton EPBZ21 User Manual
Advanced Monitored
ePDUs
Switched ePDUs
6
eaton corporation
ePDU
Managed ePDUs offer data centre
managers maximum functionality
and flexibility, with complete
understanding and control of data
centre power distribution.
Advanced Monitored ePDUs give
the data centre manager the
detailed accurate information and
understanding needed to run the
data centre efficiently and
effectively.
Switched ePDUs give control to the
data centre manager. They provide
the ability to remotely shut off or
restart equipment ensuring that it
starts up in the correct sequence
with the correct delays – together
with overall monitoring for load
balancing.
Monitoring
Monitoring
Monitoring
Highly accurate individual outlet, user-
defined group of outlets, branch circuit,
and full ePDU monitoring for kWhrs, V, W
and A (1% accuracy above 2A). Also
temperature and humidity monitoring in
the rack via optional sensors.
Highly accurate individual outlet, user-
defined group of outlets, branch circuit
and full ePDU monitoring for kWhrs, V, W
and A (1% accuracy above 2A). Also
temperature and humidity monitoring in
the rack via optional sensors.
Highly accurate monitoring of branch circuit
and the ePDU as a whole for kWhrs, V, W
and A (1% accuracy above 2A). Also
temperature and humidity monitoring in
the rack via optional sensors. Monitor over
Ethernet or via Advanced LCD screen on
the unit.
Switching
Switching
Switching
IIndividual outlet, sequencing of outlets
with delays or cycling, together with user-
defined outlet group or branch circuit,
enables remote reboot of equipment.
Power Scheduling of outlets or outlet
groups also available.
—
On, off and reboot control of individual
outlets and user-defined group of outlets,
together with cycling and sequencing of
outlets and branch circuits. Power
Scheduling of outlets or outlet groups also
available.
Control
Control
Control
Monitor and control remotely over
Ethernet or via Advanced LCD screen on
the unit. Communication protocols include
HTTP/ HTTPS, DHCP, SNMP v1 and v3,
SNTP, SMTP, Telnet, IPv4 and IPv6.
Mass configuration and upgrade available.
Includes Eaton’s patented flexible
Includes Eaton’s patented flexible
mounting system, which ensures ePDUs
will fit in any standard 42U IT rack. Eaton
Managed ePDUs provide reliable,
consistent power distribution at
temperatures of up to 50°C.
Cisco EnergyWise compliant.
Monitor and measure key properties
and alerts remotely over Ethernet or
via Advanced LCD screen on the unit.
Communication protocols include
HTTP/HTTPS, DHCP, SNMP v1 and v3,
SNTP, SMTP, Telnet, IPv4 and IPv6.
Mass configuration and upgrade available.
Includes Eaton’s patented flexible
Includes Eaton’s patented flexible
mounting system, which ensures
ePDUs will fit in any standard 42U IT rack.
Eaton Advanced Monitored ePDUs
provide reliable, consistent power
distribution at temperatures of up to 50°C.
Cisco EnergyWise compliant.
Monitor and Control key properties and
alerts remotely over Ethernet. Monitor via
Advanced LCD screen on the unit.
Communication protocols include HTTP/
HTTPS, DHCP, SNMP v1 and v3, SNTP,
SMTP, Telnet, IPv4 and IPv6. Mass
configuration and upgrade available.
Includes Eaton’s patented flexible
Includes Eaton’s patented flexible
mounting system, which ensures
ePDUs will fit in any standard 42U IT rack.
Eaton switched ePDUs provide reliable,
consistent power distribution at
temperatures of up to 50°C.
Cisco EnergyWise compliant.
Managed ePDUs