Art Finex Co. Ltd. 3680 User Manual

Page of 1
 
RFID Reader/Writer Unit
 
AMG3002 
Product Code: ASK3680 
AMG3000 Series Electromagnetic Inductive RFID System 
13.56MHz Middle Power RFID Reader/Writer Unit 
 
Instruction Sheet
 
7 Sep. 2017 
Precautions for Safe Use 
Observe the following precautions when using this product 
Suitability for Use 
Take all necessary steps to determine the suitability of the product for the systems, 
machines, and equipment with which it will be used. Know and observe all 
prohibitions of use applicable to this product.   
 
THE QUALITY LEVEL OF THIS PRODUCT IS LIMITED TO A GENERAL 
USE. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING 
SERIOUS RISK TO LIFE OR PROPERTY, SUCH AS NUCLEAR CONTROL 
SYSTEM, RAILROAD SYSTEM, AVIATION SYSTEM, VEHICLES, 
COMBUSTION SYSTEM, DIALYSIS EQUIPMENT, LIFE-SUPPORT 
EQUIPMENT, OR SAFETY EQUIPMENT. 
FOR USE WITH SERIOUS RISK TO HUMAN LIFE OR PROPERTY, OR FOR 
USE UNDER CONDITIONS NOT DESCRIBED IN THE SPECIFICATIONS, 
ART FINEX CO., LTD. WILL NOT MAKE ANY WARRANTY AGAINST THE 
PRODUCTS AND RESULTS OF USING IT.   
Class A Product 
This is a class A product. In residential areas it may cause radio interference, in 
which case the user may be required to take adequate measures to reduce 
interference. 
Ensure a minimum distance of 23 cm between antenna and human bodies. 
Specifications 
General Specifications 
Item 
Specification 
Product Name 
RFID Reader/Writer Unit 
Model Name 
AMG3002 
Power supply voltage 
12VDC to 24VDC(±10%) 
Current (Power) consumption   
0.4A max ( 3W max ) 
Ambient operating temperature 
-10 to +60ºC(with no icing) 
Ambient operating humidity 
30% to 80%RH(with no condensation) 
Ambient strage temperature 
-20 to +70ºC(with no icing) 
Ambient strage humidity 
30% to 80%RH(with no condensation) 
Host Interface 
Half-Duplex RS485 (Isolated) 
Carrier frequency 
13.56MHz 
Supporting RFID standards 
ISO/IEC 15693 
Type of modulation 
Amplitude Shift Keying (ASK) 
Conducted power 
Up to 27dBm (without antenna gain) 
Output field strength 
(with AT1M12 anntenna) 
Up to 63dBuV/m at 3m 
Up to 15dBuV/m at 30m 
Antenna connections 
2 channels (RP-SMA Female connector) 
Supporting Antenna 
ART Finex AT1M12 
Supporting IC Tags 
The IC Tags conforming to ISO/IEC 15693   
Tag-it HF-I Plus/Pro/Standard 
I-CODE SLI/I-CODE SLIX 
SRF55V10P/SRF55V02P 
MB89R116/MB89R118/MB89R119 
Weight 
Approx. 110g 
Housing Material 
Nylon66, PC 
Mounting method 
35 mm width DIN rail (EN 50022) 
Standard Accessories 
Phenix Contact #2713722 
Ferrite core for power cable 
Dimensions 
 
Control Panel 
 
Indicator LED 
Indicator 
Off 
Green 
Orange 
Red 
RUN 
Power Off 
Running 
Initializing 
Updating   
firmware 
COM 
Command 
waiting 
Command 
processing 
Recieve error 
(RS-485) 
Send error 
(RS-485) 
ERR 
No error 
Command 
succeeded 
Antenna 
disconnected*
1
 
Command failured 
/System failure*
2
 
OPT 
Controllable by command 
ANT1/ANT2 
Antenna 
disconnected 
Antenna 
connected 
Command 
processing 
Command 
failured 
*1  The  LED  lights  up  when  the  antenna  is  not  connected  to  either  connector  of  ANT1  / 
ANT2. 
*2  When the system fails, the LED (Red) is always on. 
DIP Switches 
The setting contents of DIP switches SW1 and SW2 are reflected at startup.   
If you change the settings of the SW1 and or SW2 during operation, the setting 
contents will not be reflected until reset or power is turned on again. 
Function 
Position 
On 
  Off 
 
 
Controler ID*
1
 
SW1-1 
+1 
ID can be set from 0 to 31
 
Ex. ID:18(2+16) 
SW1-2 
+2 
SW1-3 
+4 
SW1-4 
+8 
SW1-5 
+16 
Write Verify 
SW1-6 
Off 
On 
Verify after Write command 
Reserved 
SW1-7 
Fixed 
Please use at the Off position 
SW1-8 
Fixed 
Please use at the Off position 
Baud Rate 
SW2-1  (SW2-1,SW2-2) RS-485 baud rate 
(OFF,OFF):9,600bps,
 
(On,Off):19,200bps 
(OFF,On):38,400bps,
 
(On,On):115,200bps 
SW2-2 
Data Length 
SW2-3 
8bit 
7bit 
RS-485 data length 
Parity Bits 
SW2-4  (SW2-1,SW2-2) RS-485 parity bits 
(OFF,OFF):Non-Parity,
 
  (On,Off):Non-Parity 
(OFF,On):Odd Parity,
 
  (On,On):Even Parity 
SW2-5 
Stop Bits 
SW2-6 
1bit 
2bit 
RS-485 stop bits 
Protocol 
SW2-7 
ASI 
AMG 
Interface protocol type 
Terminate*
2
 
SW2-8 
On 
Off 
RS-485 Terminating resistance 
*1  The Controller ID is the sum of the values specified by SW1-1 to SW1-5. 
When installing multiple devices on the bus, please set different ID each other devices. 
*2  Please turn on only device located at the end of bus. 
Installation 
Wiring 
 
Pin assign of Bus connector 
 
Phoenix Contact 
#2713722 
Pin  Signal 
Type 
Description 
① 
SG 
RS-485 
Connect to SG terminal of RS-485 
② 
TRX+ 
RS-485 
Connect to (+) terminal of RS-485 
③ 
TRX- 
RS-485 
Connect to (-) terminal of RS-485 
④ 
VCC 
Power 
Connect to (+) terminal of Power 
⑤ 
GND 
Power 
Connect to (-) terminal of Power 
Phoenix Contact MINI COMBICON MC 3.81 mm pitch plug 1.5/5-ST-3.81 series 
connector is recommended for harness connection to bus connector (#2713722). 
 
Connector installation 
 
Attach the bus connector #2713722 to the fixed DIN rail, and then mount the 
AMG3002 after wiring the cables. 
Mounting to DIN Rail 
When mounting the AMG3002 to DIN Rail, 
① Hook the housing to DIN Rail at the point 
indicated in the figure. 
② Push down the housing in the direction 
shown in the figure until it is fixed. 
●  Allways turned off the power supply when 
mounting the AMG3002 to DIN Rail. 
 
 
Removing from DIN Rail 
When removing the AMG3002 from DIN 
Rail,   
① While pulling the metal fitting at the bottom 
of the housing in the direction shown in the 
figure, 
② Lift the housing in the direction shown in 
the figure. 
●  Allways turned off the power supply when 
removing the AMG3002 from DIN Rail. 
 
 
Regulations and Standards 
FCC CAUTION 
Changes or modifications not expressly approved by the party responsible for 
compliance could void the user’s authority to operate the equipment.   
- Properly shielded and grounded cables and connectors must be used for connection 
to host computers and/or peripherals in order to meet FCC emission limits. 
- AC adaptor with ferrite core must be used for RF interference suppression.   
Note
This equipment has been tested and found to comply with the limits for a Class A 
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to 
provide reasonable protection against harmful interference when the equipment is 
operated in a commercial environment. This equipment generates, uses, and can 
radiate radio frequency energy and, if not installed and used in accordance with the 
instruction manual, may cause harmful interference to radio communications. 
Operation of this equipment in a residential area is likely to cause harmful 
interference in which case the user will be required to correct the interference at his 
own expense. 
 
Notice for Korea Radio Law 
해당  무선설비는  전파혼신  가능성이  있으므로  인명안전과  관련된  서비스는  할  수 
없습니다 
A  급  기기  (업무용  방송통신기자재) 
이  기기는  업무용  환경에서  사용할목적으로  적합성평가를  받은  기기로서가정용 
환경에서  사용하는  경우전파간섭의  우려가  있습니다.   
본  기기는  통상  이용  상태의  경우  인체(머리,  몸통)와  20cm  초과하는  거리에서 
사용되어야  합니다 
 
Notice for Taiwan Radio Law 
低功率電波輻射性電機管理辦法 
第十二條 
經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更頻
率、加大功率或變更原設計之特性及功能。 
第十四條 
低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應立
即停用,並改善至無干擾時方得繼續使用。 
前項合法通信,指依電信法規定作業之無線電通信。 
低功率射頻電機須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾。 
 
Contact 
■ART Finex Co., Ltd. Tokyo Office 
Uchikanda282 5F, 2-15-9, Uchikanda, Chiyoda-Ku, Tokyo, Japan 
Tel: +81 (0)3 3526 3870 
Fax: +81 (0)3 5289 7352 
https://artfinex.co.jp/contact/ 
Copyright© ART Finex Co., Ltd., 2011-2017, All Rights Reserved. 
Reproduction, distribution, or modification in whole or in part is prohibited without 
the prior written consent of ART Finex Co., Ltd. 
The information contained in this manual is subject to change without notice. Every 
precaution has been taken in the preparation of this manual. Nevertheless, 
ART Finex assumes no responsibility for errors or omissions. Neither is any liability 
assumed  for  damages  resulting  from  the  use  of  the  information  contained  in  this 
publication. 
 99 ±0.4
 1
13
.6
 1
07
+ -
0.5
5
0.4
0
 22.60
+
-
0.35
0.30
(mm)
AMG3002
Po
w
er
Su
pp
ly
TRX+
TRX-
SG
H
os
t
Sy
st
em TRX+
TRX-
SG
+
-
VCC
GND
Ferrite Core
Shielded Twisted Pair Cable
(Accessorie)
WARNING
 
The  following  contents  which  may  lead  to  death  or 
serious injury. 
 
●  Do not use the product in environments subject to inflammable, explosive, or 
corrosive gases. 
●  Do not disassemble, modify, or repair this product in any way.   
●  Do not pour water or insert wire in the gaps of the case. 
●  Do not touch this product with wet hands. 
●  Confirm that the DC power supply voltage is within the rated power supply 
voltage (12 VDC-24 VDC) before using it. 
●  Do not use this product for purposes other than communicating with IC tags. 
●  This product must be operated with a minimum separation distance of 23 cm 
(8.7inch) or more from a person's implanted medical device such as cardiac 
pacemakers. 
CAUTION
 
The  following  contents  which  may  lead  to  serious 
personal injury or damage to property.
 
●  Always turn off the power supply before attaching or removing the product and 
antenna cable. 
●  Make sure that the wiring is correctly connected and securely fixed. 
●  Do not reverse polarity when connecting the power supply. 
●  Do not connect anything other than a dedicated antenna to the antenna terminal. 
●  Do not cut, damage or modify the antenna cable. Do not pull, bend or twist the 
cable with unnecessary force. Do not place heavy objects on the cable or allow 
the cable to get pinched in between objects. 
● 
If you suspect that anything is wrong with the product at any time, stop using it 
immediately, turn off the power supply.
 
● 
This product is a communication facility using radio waves of 13.56 MHz which 
is the ISM band which can be generally used. For this reason, interference may 
occur depending on the application and location to be used. In order to minimize 
the influence of this interference, please be confirmed prior to installation. Also, 
there is a danger of affecting radio astronomy and medical equipment, etc. 
Please pay particular attention to the use in such an environment.
 
●  Do not store / install the product in the following locations : 
  Locations subject to flammable, explosive, corrosive gases, dust, metal 
powder or salt. 
  Locations subject to contact with water, oil, or chemicals. 
  Locations where the temperature and humidity conditions specified in the 
specification are exceeded or locations where the temperature changes 
drastically (where dew condensation occurs). 
  Locations subject to outside or direct sunlight. 
  Locations subject to shock or vibration. 
  Locations subject to near morter, high-voltage or high-current wiring. 
  Locations subject to strong electromagnetic field, static electricity occurs. 
● 
  When disposing of the product, dispose of it as industrial waste. 
 
●  Wrap the power cable 3 times around the ferrite core of the accessory, install it 
within about 9 cm from the AMG3002 side. 
●  Use cables with a length of 3 m or less for signal and power wiring. 
●  Use shielded twisted pair cable for signal wiring and connect signal ground (SG) 
to shielded wire of twisted pair cable. 
 
●  Check the polarity of the power supply / signal line and that the cable connection 
is correctly performed. 
●  Use the DIN rail by grounding (grounding resistance 100 Ω or less). 
●  Use a power supply whose voltage fluctuation range is within the rated range and 
has sufficient margin in output capacity.