HQPOWER 
 
DMX-Controlled Mode 
 
Channel 
Function 
From 
To 
Description 
127 
Dimmer from 0 to 100% 
128 
250 
Strobe from 0 to 100% 
Dimmer / Strobe 
251 
255 
Open 
Red 
255 
From 0 to 100% 
Green 
255 
From 0 to 100% 
Blue 
255 
From 0 to 100% 
 
 
DMX512 Connection 
 
Connect the provided XLR cable to the female 3-pin XLR output of your controller and the other side to the 
male 3-pin XLR input of the VDPLW810. Multiple VDPLW810s can be linked through serial linking. The linking 
cable should be a two-core screened cable with XLR input and output connectors. 
 
 
DMX512 Chain with Termination 
 
A DMX terminator is recommended for installations where the DMX cable has to run a 
long distance or is in an electrically noisy environment (e.g. discos). The terminator 
prevents corruption of the digital control signal by electrical noise. The DMX terminator is 
simply an XLR plug with a 120Ω resistor between pins 2 and 3, which is then plugged into 
the XLR output socket of the last device in the chain. 
Please see illustrations. 
 
 
DMX Start Address Selection 
 
All DMX-controlled devices need a digital start address so that the correct device responds to the signals. This 
start address is the channel number from which the device starts to “listen” to the DMX controller. Enter the 
correct number and read it from the display located on the base of the VDPLW810
You can use the same starting address for a whole group of devices or enter an individual one for every 
device. 
When all devices have the same address, all the VDPLW810s will “listen” to the control signal on one 
particular channel. In other words: changing the settings of one channel will affect all devices simultaneously. 
If you set different addresses, each device will “listen” to a separate channel number. Changing the settings of 
one channel will only affect the device in question. 
In the case of the 4-channel VDPLW810, you will have to set the start address of the first VDPLW810 to 1, the 
second VDPLW810 to 5 (1 + 4), the third to 9 (5 + 4) and so on. 
 
6. Cleaning and Maintenance 
 
1.  All screws should be tightened and free of corrosion. 
2.  The housing, visible parts, mounting supports and the installation location (e.g. ceiling, suspension, trussing) 
should not be deformed, modified or tampered with e.g. do not drill extra holes in mounting supports, do not 
change the location of the connections. 
3.  Moving mechanic parts must not show any signs of wear and tear. 
4.  The electric power supply cables must not show any damage. Have a qualified technician maintain the device. 
5.  Disconnect the device from the mains prior to maintenance activities. 
6.  Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents. 
7.  There are no user-serviceable parts. 
8.  Contact your dealer for spare parts if necessary.