o  CID: command ID to identify one specific command initiated from LoRa server, below table 
shows all the commands: 
CID 
Command 
Format#  Comment 
0x2 
PlssReboot 
Reboot WxS8000 immediately 
0x8 
PlssGetInfo 
Get WxS8000 management information, 
WxS8000 should respond this with Mote 
information report message in next uplink 
transmission window 
0x13 
PlssSetPPB 
Set specific attribute in WxS8000 PPB 
(Polysense Proprietary Base) 
0x14 
PlssSetPRB 
Set specific attribute in WxS8000 PRB 
(Polysense Runtime Base) 
0x15 
PlssSetClk 
Set WxS8000 local date-time to align with the 
server 
0x19 
PlssSetExtCntr 
Set the counter of the external counter sensor 
to the value specified in Value field 
0x1A 
PlssGetPPB 
Get specific attribute in WxS8000 PPB, and 
there is NO Value parameter in format#3 above 
 
o  Value: the value to be set to WxS8000 
o  Attribute: identify one specific attribute in PPB or PRB 
o  ValueLength: the length of the value in octet  
 
If the FRMPayload length allows (the MAX FRMPayload length is region-dependent), LoRa 
server can pack multiple downlink messages together and fill into the FRMPayload of one LoRa 
frame in order to improve the transmission efficiency. Once WxS8000 receives the frame, it will 
parse out all the messages, and process one by one. 
 
If there is PlssReboot message inside the FRMPayload which consists of multiple messages, 
then WxS8000 won’t execute reboot until all other messages are handled 
 
4.1.1.  Set Individual Attribute in PPB (PlssSetPPB) 
The change to PPB attributes can take effect immediately except the change of REGION, which will take 
effect only after WxS8000 reboot or power recycle. 
4.1.1.1. General Attributes 
Attribute  Description 
ValueLength 
(bytes) 
Value 
Comment 
0x2 
REGION 
0 – US902 
LoRa region setting. WxS8000 supports all the regions as 
defined in LoRaWAN spec 1.0.2, besides WxS8000