Data[1] ….. Y data for #0 sampling in unit of 1mg
Data[2] ….. Z data for #0 sampling in unit of 1mg
Data[3] ….. X data for #1 sampling in unit of 1mg
Data[4] ….. Y data for #1 sampling in unit of 1mg
Data[5] ….. Z data for #1 sampling in unit of 1mg
……
Data[297] ….. X data for #99 sampling in unit of 1mg
Data[298] ….. Y data for #99 sampling in unit of 1mg
Data[299] ….. Z data for #99 sampling in unit of 1mg
Data[2] ….. Z data for #0 sampling in unit of 1mg
Data[3] ….. X data for #1 sampling in unit of 1mg
Data[4] ….. Y data for #1 sampling in unit of 1mg
Data[5] ….. Z data for #1 sampling in unit of 1mg
……
Data[297] ….. X data for #99 sampling in unit of 1mg
Data[298] ….. Y data for #99 sampling in unit of 1mg
Data[299] ….. Z data for #99 sampling in unit of 1mg
Frame #0 reported by WxS8000:
D7-7F-01-80-00-Data[0]-Data[1]-Data[2]-…[Data[95]
Frame #1 reported by WxS8000:
D7-7F-02-80-00-Data[96]-Data[97]-Data[98]-…[Data[191]
Frame #2 reported by WxS8000:
D7-7F-03-80-00-Data[192]-Data[193]-Data[194]-…[Data[287]
Frame #3 reported by WxS8000:
D7-7F-04-00-00-Data[288]-Data[289]-Data[290]-…[Data[299]
Frame #4 reported by WxS8000:
D7-7F-00-00-00
Frame responded by LoRa server if all frames are received correctly:
16-00
Frame responded by LoRa server if uplink frame#2 is missed:
16-03
WxS8000 should retransmit Frame#2 to Frame#3, then resend Frame#4 to confirm again.
4.2.3. Mote Information Report
As the response to PlssGetInfo message from LoRa server, WxS8000 should report below mote
information to LoRa server in next uplink transmission window after it receives the PlssGetInfo
message.
Size (bytes)
4
4
4
MSGPayload
Version
SysTick
(Reserved)
o Version: WxS8000 firmware version, for example, R1.2.3.4 is represented as 0x01020304 in
the message