Spaun HLV 40/65 FPE 813129 User Manual
Product codes
813129
Model
Art. No.
HNV 30/30 UPE
811267
HNV 30/65 UPE
811268
HNV 30 UPE
811269
HNF 30 URP
811304
HNV 20 U
811273
Inputs / Outputs
1 / 1
1 / 1
1 / 1
1 / 1
1 / 1
Frequency Range
47 ... 862 MHz
85 ... 862 MHz
47 ... 862 MHz
47 ... 862 MHz
47 ... 862 MHz
Return Path passive
5 ... 30 MHz
5 ... 65 MHz
-
-
-
Screening Factor
> 85 dB
Gain
20 or 30 dB
20 or 30 dB
20 or 30 dB
20 or 30 dB
10 or 20 dB
Max. Outputlevel
60 dBµV IMA
60 dBµV IMA
3
/ EN 50083-3
108 dBµV
108 dBµV
108 dBµV
108 dBµV
109 dBµV
Level Adjusting Range
0 ... -12 dB
0 ... -12 dB
0 ... -12 dB
0 ... -12 dB
-
Slope Equalizer
0 ... -15 dB
0 ... -15 dB
0 ... -15 dB
0 ... -15 dB
-
Noise Figure
< 7 dB
< 7 dB
< 7,5 dB
< 7 dB
< 8,5 dB
Remote Powering
15 ... 20 V / 210 mA
15 ... 20 V / 210 mA
-
15 ... 20 V / 210 mA
-
Mains Power Supply U~
100 ... 240 V / 50 Hz
100 ... 240 V / 50 Hz
100 ... 240 V / 50 Hz
-
230 V / 50 Hz
Power Consumption
< 4 W
< 4 W
< 4 W
-
< 6 W
Ambient Temperature
-20 ... +50 °C
-20 ... +50 °C
-20 ... +50 °C
-20 ... +50 °C
-20 ... +50 °C
Dimensions in mm
194 x 86 x 52
194 x 86 x 52
194 x 86 x 52
138 x 83 x 52
160 x 86 x 52
• Forward gain in two stages selectable
•
Integrated Level Adjuster and Slope Equalizer
• For UC plants after the point of transfer or as line
amplifiers as well as MATV amplifiers in GA/ATM plants
•
amplifiers as well as MATV amplifiers in GA/ATM plants
•
Metal / plastic housing for indoor mounting
Return Path passive
47 ... 862 MHz
Return Path passive
5 ... 65 MHz
85 ... 862 MHz
contact@spaun.de
Home Distribution-, MATV-, CATV-
and Line Amplifier
HNV 30/65 UPE, HNV 30/30 UPE, HNV 30 UPE,
HNF 30 URP, HNV 20 U
Quality made in Germany