Danfoss Power Solutions Company WMSS1000 User Manual

Page of 11
Technical Information 
WMSS1000 Wireless Multi-Sonic 
Sensor
 
Connector Pin Assignments 
During normal operation, the connector on the wireless sensor is capped (insert a 
photo, to come (Kim?)).  Remove this cap to attach the battery charger or to attach 
the connector for the  PLUS+1 Service Tool. 
 
 
 
 
 
 
 
 
 
 
Welding Procedures 
Remove the sensors from the machine before any welding.  Remember the sensor 
mounts contain an RFID which can be damaged.  The following procedures are 
recommended when welding on a machine equipped with sensors: 
•  Turn the engine off. 
•  Disconnect the negative battery cable from the battery. 
•  Do not use electrical components to ground the welder. 
•  Clamp the ground cable for the welder to the component that will be welded as 
close as possible to the weld. 
Pin 
Controller Function 
Description 
Notes 
Power Input 
PWR_1 
 
Power Ground 
GND 
 
CAN HI 
CAN1_1_HI 
 
CAN LO 
CAN1_1_LO 
 
CAN SHIELD 
CANSHIELD1_1 
There is a 0.68 uF capacitor and 
a 1 Ohm resistor in series to 
ground on this input for CAN 
shield termination. 
SHORT TERM CONFIDENTIAL