Vivint. Inc. CP02 User Manual

Page of 92
Configure System Settings: Reporting and Troubles Settings
- 45 -
Reporting and Troubles Settings
This section contains descriptions, default values, and notes about the Reporting and Troubles settings.
To access these settings from the control panel, go to:
Menu > Settings > Installer Toolbox > Reporting and Troubles
From the Networking screen, you can view and configure the following settings.
Programming Mode Entry Reports to CS
DEFAULT: Disabled
A report can be sent to the Central Station any time programming (i.e., system settings configuration in the 
Installer Toolbox) mode is entered and exited.
 
The default setting prevents reporting programming mode entry and exit.
 
To report programming mode entry and exit, select enabled.
Trouble Reports to CS
DEFAULT: Enabled
Trouble reports can be sent to the Central Station when any sensor trouble condition occurs.
 
The default setting allows reporting sensor trouble conditions.
 
To not report sensor trouble conditions, select disabled.
NOTE: This setting does not affect trouble reports caused by control panel conditions, only trouble reports caused 
by sensors.
Trouble Restore Reports to CS
DEFAULT: Enabled
Trouble restore reports can be sent to the Central Station when any sensor trouble condition clears.
 
The default setting allows trouble restore reports.
 
To turn off trouble restore reports, select disabled.
Manual Bypass Reports to CS
DEFAULT: Disabled
Manual bypass reports can be sent to the Central Station when any sensor has been manually bypassed by the 
user.