Shenzhen Kelvin Electronics Co. Ltd. KL180-4 User Manual

Page of 3
Specification  of  KL180-4  KL180-2  KL180C-4  KL180D-4  
KL180E-4  
Parameter: 
Working Voltage:DC12V 
Working Current:10mA 
Frequency:433.92MHz 
Modulation:ASK 
Temperature:-20-55℃ 
Dimension:55*30*13.5mm 
Weight : 28.2g 
Encode type: Learning code  
 
Operation Method: 
1. Match code:  
Hold learning button and learning indicator light blinks, then press any buttons of remote control, 
if indicator lights flashes 3 times, match code successfully. Maximum 80 remote controls can be 
matched. 
2. Delete code:  
Hold learning button till the indicator LED lights and then off, delete successfully. 
  
3. Set working mode:  
S1 & S2 program the sequence as follows:  
Jumper on S1→ Toggle 
Jumper on S2→ Latched 
No Jumper on S1 &S2→ Momentary