Shenzhen Kelvin Electronics Co. Ltd. KL180-4 User Manual
Specification of KL180-4 KL180-2 KL180C-4 KL180D-4
KL180E-4
Parameter:
Working Voltage:DC12V
Working Current:10mA
Frequency:433.92MHz
Modulation:ASK
Temperature:-20-55℃
Dimension:55*30*13.5mm
Weight : 28.2g
Encode type: Learning code
Operation Method:
1. Match code:
Hold learning button and learning indicator light blinks, then press any buttons of remote control,
if indicator lights flashes 3 times, match code successfully. Maximum 80 remote controls can be
matched.
2. Delete code:
Hold learning button till the indicator LED lights and then off, delete successfully.
3. Set working mode:
S1 & S2 program the sequence as follows:
Jumper on S1→ Toggle
Jumper on S2→ Latched
No Jumper on S1 &S2→ Momentary
Jumper on S1→ Toggle
Jumper on S2→ Latched
No Jumper on S1 &S2→ Momentary