Figure 78  - Alarm Threshold Management 
5.4.13.2 Alarm Monitoring and Thresholds - Configure alarm monitoring and threshold attributes. 
•  Alarm Name  
Identifies the alarm 
•  Measured Object   The parameter in the unit subject to monitoring and threshold comparison 
•  Observed Value  
The value of the measured object which caused the last alarm state change 
•  Monitor Interval   The frequency in seconds that the measured object is checked against the 
configured thresholds 
•  Raise Intervals          The number of consecutive monitoring intervals required where the observed 
measured object value has crossed the raise threshold before the alarm is finally 
raised.  
•  Clear Intervals          The number of consecutive monitoring intervals required where the observed 
measured object value has crossed the clear threshold before the alarm is finally 
cleared.  
•  Raise Operation   The comparison operator used when comparing the measured object’s  value 
against the raise threshold for determining the alarm is in the raised state.  
•  Raise Threshold   The raise alarm threshold value   
•  Clear Operation  
The comparison operator used when comparing the measured object value against 
the clear threshold for determining the alarm is in the cleared state.  
•  Clear Threshold  
The clear alarm threshold value   
•  Alarm State  
Colour coded state showing severity for raised alarms 
•  Alarm Time  
The time of the last alarm state change 
Note: For a measured object based on statistical history (e.g. 1m, 15m etc..) it does not make sense to set the 
monitoring interval to a value less than the update frequency of the  statistic, e.g. for 15m stats set monitoring 
interval to 900 seconds. 
5.5 
Maintenance 
The Maintenance pages are only accessible by users having the required access privileges, which are granted 
by an administrator. 
5.5.1 
Maintenance - Firmware Upgrade 
This section allows the operator to upgrade a radio terminal’s firmware. There are 2 memory banks. The 
firmware upgrade process will upload the new firmware to the INACTIVE memory bank. Therefore, before