Ever 500VA UPS Duo II Pro T/DIIPTO-000K50/00 User Manual

Product codes
T/DIIPTO-000K50/00
Page of 3
350, 500, 800, 1000 
DUO II / DUO II Pro
www.ever.eu
Output power
1)
 
Topology
Enclosure type
Tower
Off-line (VFD)
PARAMETERS
MODEL
ENVIRONMENTAL PARAMETERS
DUO II 350
DUO II Pro 350
350VA / 210W
500VA / 300W
same as input
LC
<6ms
192 x 85 x 253 mm
2,8 kg
3,7 kg
4 x IEC 320, C13
+
DUO II 500
DUO II Pro 500
~190 - 259V ± 5%
45 - 55Hz ± 1Hz
0ms
1 x 12V / 5Ah
16h
~190 - 259V ± 5%
~190 / 259V ± 5%
~230V ± 10%
~200V / 249V± 5%
50Hz ± 1Hz
1 x 12V / 7Ah
16h
3/6/10 min
4/5,5/12 min
DUO II 800
DUO II Pro 800
DUO II 1000
DUO II Pro 1000
800VA / 490W
1000VA / 600W
2 x 12V / 5Ah
10h
2 x 12V / 7Ah
10h
4/6/13 min
3/4/12 min
258 x 84 x 358 mm
6,1 kg
7,6 kg
PowerSoft Personal
Software (DUO II Pro only)
USB (DUO II Pro only)
Communication interface
Telecommunication filter
automatic
Fuse
Sound and LED
Indication
Number of output sockets                                                          
FITTINGS
4)
Altitude (above sea level) 
Up to 1000m
Work environment
Working temperature 
Storage temperature 
3
)
Relative humidity when working
Relative humidity during storage
20 - 80% 
(non condensing)
20 - 95% 
(non condensing)
Office or industrial premises
marked by a low contamination level
o
+10 - +35 C
o
0 - +45 C
Dimensions (height x width x depth)
UPS weight
Input voltage
Input voltage frequency
Switching thresholds: network - UPS
Output voltage waveform
Output voltage filtering
Output voltage range
Time to switch to battery mode
POWER NETWORK SUPPLY
BATTERY SUPPLY
MECHANICAL PARAMETERS
N
o
te
T
h
e
 m
a
n
u
fa
c
tu
re
re
s
e
rv
e
s
 t
h
e
 r
ig
h
to
 m
o
d
if
y
 t
h
e
 a
b
o
v
e
 p
a
ra
m
e
te
rs
 w
it
h
o
u
n
o
ti
c
e
.
Output voltage (RMS)
Output voltage frequency
Output voltage waveform
Switching thresholds: UPS - network
Short circuit protection
Overload protection
Time to switch to network mode
Battery
Maximum charging time
Backup time 100%/80%/50% Pmax
modulated sine wave
electronic
electronic
1) For normal operation of the battery back-up the load connected to its output should not exceed 80% of value indicated in the table. Reserve power is essential to ensure continuous operation of 
connected devices in case of momentary rushes in load current.
2) After discharging the UPS with 0.8 Pmax power – charging the battery to 80% capacity.
3) Continued exposure of the battery back-up to the ambient temperature exceeding +25°C will shorten the life of batteries.
4) If the altitude above sea level increases beyond the provided limit the permitted load power of the batter back-up decreases.