Shenzhen Minde Electronics Technology LTD. MS3590 User Manual

Page of 109
 
  47 
7-6 UPC-E 
Read:   
Format 
System character “0” 
Data digits (6 digits) 
Check digits 
Check digit verification: The check digit is optional and made as the sum of the numerical value of the 
data digits.   
Check digit trans.: By setting Enable, check digit will be transmitted.   
Code ID setting: Refer to Code ID setting of 
.
 
Insertion group selection: Refer to Insertion group selection of 
Supplement digits: 
Format 
System character “0” 
Data digits (6 digits) 
Check digit  Supplement digits 2 or 5 
Truncation/Expansion: 
Truncate leading zeros- Refer to Truncation/Expansion of 
Expand to EAN-13- It extends to 13-digits with “0” digits when the feature is set to be enabled. 
Example: Barcode “0123654”,   
Output: “0012360000057”. 
Expand to UPC-A- It extends to 12-digits when the feature is set to be enabled. 
Truncate  system  character-  The  system  character  “0”  of  UPC-E  data  can  be  truncated  when  the 
feature is enabled.