Cinch Systems Inc RF-CHW User Manual

Page of 2
Hardwire to Wireless Converter 
RF-CHW-ITI-16 
 
 
 
 
 
 
 
Description: 
The RF-CHW-ITI-16 module allows the conversion 
of hardwire security sensors to Qolsys wireless 
technology. The module is a cost effective way of 
upgrading a security system and using existing 
hardwire security zones. The module supports  both 
magnetic contacts and powered zones (12VDC) as 
motion detectors.  The module uses the existing 
EOL resistors so no re-wiring or changing out EOL’s 
is required. 
 
Installation: 
Mounting location - if retrofitting an existing hard-
wire control panel, mount the module at that loca-
tion to minimize splicing wires. 
Note: if possible use the existing enclosure to house 
the module and battery, remember the antenna on 
the module must protrude from any metal enclo-
sure. 
 
Wiring  (see wiring diagram)  
 
Power transformer - 2 conductor 
 
Zone wiring - from existing control panel  
 
Zone power  
 
Siren extension  
 
Backup battery 
 
Note: use 22 AGW minimum 
 
Note:  Make sure EOL resistors remain in place for 
all zones 
 
RF-CHW-ITI-16 
Programming: 
The RF-CHW-ITI-16 module is a wireless device that 
enrolls into the Qolsys control panel. The module has 
a unique ID # that the control panel responds to for 
tamper and low battery conditions. Also each zone is 
assigned it’s own ID# for reporting purposes. 
 
Module setup: 
Clear Memory: 
  Disconnect all power battery and transformer, 
press and hold the memory reset button while 
applying power 
  The LED’s will flash indicating memory reset 
  Power module by plugging in the transformer 
and connecting backup battery if required 
 
Notes
:  
  Polarity on transformer marked as dashed line 
on positive wire 
  Make sure all input EOL’s are properly wired for 
N/O (parallel) or N/C (series) configuration 
  All zones must be wired with an EOL resistor, 
either a 3K ohm from the accessory kit or the 
existing resistor from the previous system 
  Place all zones in normal non alarm condition 
 
Enrolling module and zones into the Qolsys panel - if 
the module tamper and battery supervision are re-
quired the module must be enrolled into the control 
panel (this step not required if no backup battery or 
tamper are used) 
 
Enroll module, EOL’s and zones 
  Put the module in Learn Zone mode by pressing 
the EOL Learn button and holding for 5 seconds, 
all LEDs will flash, this process also learns in all of 
the EOL’s 
  Enter system programming on the Qolsys panel 
  Settings menu, enter user code 
  Installation menu, Security Sensors, 
Auto Learn  
        Sensor 
  To enroll the module trip the tamper zone  
  The Qolsys panel will indicate a sensor has been 
detected and require pressing the control panel 
OK to add the sensor 
  The Qolsys panel will display sensor characteris-
tics that can be changed if required, when com-
plete press Add New 
  The Qolsys panel returns to the Auto Learn Sen-
sor and waits for the next sensor to be activated 
  Continue enrolling zones by activating the zone, 
the Qolsys panel will respond with each success-
ful wireless activation and required zone type 
and name selection before the next zone is 
tripped. 
  After all zones are enrolled press the EOL Learn 
Button to exit program mode on the module, all  
LED’s will go out 
 
Note: Learning zones cannot be done if the EOL Cali-
bration LED is Flashing or Off 
 
 
Testing 
  On the Qolsys panel enter Settings, enter user 
code 
  Press System Test, Sensor Test 
  Activate all zones on the module and verify they 
Pass 
 
 
FCC label statement: 
“This device complies with part 15 of the FCC Rules. Operation is subject to 
the following two conditions: (1) This device may not cause harmful interfer-
ence, and (2) this device must accept any interference received, including 
interference that may cause undesired operation.” 
“Note: This equipment has been tested and found to comply with the limits 
for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits 
are designed to provide reasonable protection against harmful interference 
in a residential installation. This equipment generates, uses and can radiate 
radio frequency energy and, if not installed and used in accordance with the 
instructions, may cause harmful interference to radio communications. 
However, there is no guarantee that interference will not occur in a particu-
lar installation. If this equipment does cause harmful interference to radio or 
television reception, which can be determined by turning the equipment off 
and on, the user is encouraged to try to correct the interference by one or 
more of the following measures: 
—Reorient or relocate the receiving antenna. 
—Increase the separation between the equipment and receiver. 
—Connect the equipment into an outlet on a circuit different from that to 
which the receiver is connected. 
—Consult the dealer or an experienced radio/TV technician for help.” 
“Changes or modifications not expressly approved by the party responsible 
for compliance could void the user's authority to operate the equipment” 
 
“RF Exposure Guidance: This equipment complies with FCC radiation expo-
sure limits set forth for an uncontrolled environment. This equipment should 
be installed and operated with a minimum distance of 1.5cm between the 
radiator and persons. This transmitter must not be co-located or operating in 
conjunction with any other antenna or transmitter, except in accordance 
with FCC multi-transmitter product procedures.”