Honeywell Security Sensor CoE PP300850SE User Manual
- 2 -
5
24-20 AWG
(0.2-0.52mm2)
2
1
2
Tamper
30 mA
25 VDC
Trouble
30 mA
25 VDC
Power
18 mA
9 - 15 VDC
Alarm
30 mA
30 mA
25 VDC
LED
0 VDC - V
supply
1.8 mA max
LED TBL
T
C
V
-
V
+
T
NC
TBL
9 8
6
4
2 1
5
3
7
EOL
KOhm
ON
1
2.2 5.6
2
EOL
WIRING EXAMPLES /
WIRING EXAMPLES / WIRING EXAMPLES
To connect alarm and tamper outputs (NO trouble) to one zone input:
All alarm and tamper events are “alarms” when the system is armed or
“fault” when disarmed.
All alarm and tamper events are “alarms” when the system is armed or
“fault” when disarmed.
(FR) To connect alarm and tamper outputs (NO trouble) to one zone
input: All alarm and tamper events are “alarms” when the system is
armed or “fault” when disarmed.
input: All alarm and tamper events are “alarms” when the system is
armed or “fault” when disarmed.
(SP) To connect alarm and tamper outputs (NO trouble) to one zone
input: All alarm and tamper events are “alarms” when the system is
armed or “fault” when disarmed.
input: All alarm and tamper events are “alarms” when the system is
armed or “fault” when disarmed.
(PG) To connect alarm and tamper outputs (NO trouble) to one zone
input: All alarm and tamper events are “alarms” when the system is
armed or “fault” when disarmed.
input: All alarm and tamper events are “alarms” when the system is
armed or “fault” when disarmed.
Zone
COM Ground +12V
Control Panel
Zone
#
LED TBL
T
C
V
-
V
+
T
NC
TBL
9 8
6
4
2 1
5
3
7
Se
n
s
o
r
EOL
KOhm
ON
1
2.2 5.6
2
EOL
(On-Board, Internal EOLR)
To connect all three outputs (sensor alarm, tamper and trouble) to
one zone input: All alarm, tamper and trouble events are “alarms” when
the system is armed or “fault” when disarmed.
one zone input: All alarm, tamper and trouble events are “alarms” when
the system is armed or “fault” when disarmed.
FR) To connect all three outputs (sensor alarm, tamper and trouble)
to one zone input: All alarm, tamper and trouble events are “alarms”
when the system is armed or “fault” when disarmed.
to one zone input: All alarm, tamper and trouble events are “alarms”
when the system is armed or “fault” when disarmed.
ES) To connect all three outputs (sensor alarm, tamper and trouble)
to one zone input: All alarm, tamper and trouble events are “alarms”
when the system is armed or “fault” when disarmed.
to one zone input: All alarm, tamper and trouble events are “alarms”
when the system is armed or “fault” when disarmed.
PG) To connect all three outputs (sensor alarm, tamper and trouble)
to one zone input: All alarm, tamper and trouble events are “alarms”
when the system is armed or “fault” when disarmed.
to one zone input: All alarm, tamper and trouble events are “alarms”
when the system is armed or “fault” when disarmed.
Zone
COM
Ground
Zone
#
+12V
Control Panel
(On-Board, Internal EOLR)
LED TBL
T
C
V
-
V
+
T
NC
TBL
9 8
6
4
2 1
5
3
7
EOL
KOhm
ON
1
2.2 5.6
2
EOL
Se
n
s
o
r