    the value.
3. Switch to other setting item:
    Press the "SET" key to switch to other item.
    F-01: Offset value for body mode(-2.0~+2.0).
    F-02: Offset value for surface mode(-2.0~+2.0).
    F-03: Temperature Unit (
O
C/
O
F).  
    F-04: Delete records(Yes,No)
4. Save setting value.
    Pressing the "SET" key for 3 seconds to save 
    the value and exit setting mode. If F-04 value is
    "YES", The thermometer will be delete all records.
- 1-
- 2-
- 3-
-4-
O
C / 
O
F unit conversion formula
O
F=1.8x
O
C+32
Cautions ..................................................2
Special Features .....................................2
Measurement Principle ...........................2
Product scope .........................................3
The component of product ......................3
Setting .....................................................3
O
C / 
O
F unit conversion formula ...............4
Method of measurement .........................4
Connect iOS device via Bluetooth ..........5
Memory Function ....................................5
Replacing the Batteries ...........................6
Cleaning and Care ..................................6
Display Message .................................... 7
Product Specifications .............................8
Contents
1. Pressing "Power" and display and showen the last 
    records.
2. Pressing the "MEM" key to switch record shows 
    upper
    * LCD display test records and record number.
3. Switch mode
    * Pressing the "MODE" key to switch MODE.
Memory Function
Method of measurement
Cleaning and Care 
1. Use a soft, dry cloth to clean the exterior of the
    thermometer.
2. Keep the thermometer away from direct sunlight, 
    dust and contamination environment.
3. Store the thermometer in normal room 
    temperature, or within 10-40
o
C.
4. Don't touch with the finger.
5. Can use less than 75% of the rubbing alcohol to 
    clean the lens.
Product specification
- 5-
- 6-
- 7-
- 8-
TET-380
±0.3
O
C
Project
5~10cm
16~35
O
C
±0.4
O
C
10~40
O
C
LCD display
<2.2V±0.3
0.1
O
C
50 Group memory
O
C , 
O
F
-20
O
C~+50 
O
C
10
O
C~40
O
C
1 minute after not being used
158.8×86.6×37.4 mm
About 93g (Not including batteries)
2 x AA
Measuring type
Measuring mode
Measuring distance
Accuracy
Memory
Automatic shutdown
Storage temperature
Work surrounding
Unit
Display resolution
Low voltage tip
Indicator Functions
Battery
Size
Weight
Content
Infrared measuring
Surface/body temperature
32~42.2
O
C
20~32
O
C
42.2~60
O
C
Measuring
Surrounding
Accuracy
Replacing the Batteries
Products use battery by 2, when a battery symbol 
appears and flash in the screen, and replace the 
battery as soon as possible.
• Note:
1. Open the battery cover to 
    replace batteries, and 
    place the battery is the 
    location of the negative 
    electrode correctly.
2. If not use, please take out 
    the battery so as to protect 
    instrument.
Pull and open 
the battery cover 
from then on
    (2) Pressing and holding the "Measure" key and
         move thermometer scaning forehead.
    (3) Release the "Measure" key to finish 
         measurement and display the result on LCD.
    (4) Turn off: The thermometer will trun off 
         automatically without use for 1 minute.
• Note:
The correct method of use is the key to test the 
accuracy. Please follow these instructions, so as to
avoid the infrared measurement on the surrounding.
1. Testing temperature, as the showing in the figure, 
    instrument and the distance from the forehead 
    suggested in 5cm to 10cm.
2. Keep the body's temperature as the same as the 
    surrounding.
3. It should be avoided cold and any disease of cool 
    down the temperature.
4. Keep the Instrument's temperature  as the same 
    as the surrounding.
5. Forbidden to use this instrument in the strong 
    sunshine place.
6. Measure suggestion: 3 times or so, every time 
    when to display up to a set of data shall prevail.
5~10cm
1. Pressing "Power" and display.
2. Press "MODE" key to select temperature 
    measurement mode (body or surface) :
    (1) Thermometer is straight  to the forehead, and 
         distance is 5~10cm.  
Power/Measure
Cranium
Display 
message
Situation
Solution 
Allow the  thermometer 
remain in room 
temperature (10-40
O
C) 
for 30 minutes. 
Ambient temperature 
is out of operating 
range (10-40
O
C)      
Sensor error
Please contact with the 
customer service.
Please contact with the 
customer service.
Temperature measured 
is higher than normal 
human temperature 
range
(Body above 42.2
O
C; 
Surface above 60
O
C)
Check the measured 
object and take a 
new measure.
Temperature measured 
is lower than normal 
human temperature
range (Body below 32
O
C; 
Body below 20
O
C) 
Check the measured 
object and take a 
new measure.
Low battery             
Replace batteries.
Memory error 
Display Message 
The component of product
For measurement of body and surface temperature.
Product scope
Setting
Back
Front
1. Pressing the “SET” Key for 3 seconds, 
    The thermometer will be turn on and enter the 
    setting mode, the LCD display F-00 and alarm 
    temperature value.
2. Modify the setting value
    Pressing the "MODE" or "MEM" key to change 
Battery cover
Body
Surface
LCD
Memory
Mode
Set
  
Thank you for purchasing the non-contact 
electronic thermometer, Please read through this 
manual before using the product. 
Cautions
1. Do not drop or shock the unit.
2. Do not immerse the unit into water.
3. Keep the unit out of reach of children.
4. Avoid touching the lens with bare hand.
5. Do not use in areas with strong electromagnetic     
    interference.
6. Consult your physician if the reading is out of normal
    body temperature range.
7. Remove the batteries from the thermometer if the
    unit will not be used for an extended period of time.
    This will prevent battery leakage causing damage
    to the thermometer.
8. If the unit is not working properly, please contact
    customer service.
9. Do not disassemble the unit, Open the battery     
    cover only when replacing batteries.
Special Features
1. Measurement range: Body: 32~42.2
O
C / 90~108
O
F
    Surface: 20~60
O
C / 68~140
O
F
2. Free to set alarm temperature.
3. Non-contact measurement ,avoid cross infection.
4. Memory for 50 readings.
5. Auto power off without use it.
6. Unit of Measure: 
O
C/
O
F.
7. Backlight. 
Measurement Principle
built-in infrared sensor and related hardware, 
software, can sense the analyte, analysis and records 
and environmental temperature, and once the user 
has to pass the instrument near certain parts of the 
body (forehead), and press the measure button can 
immediately active infrared radiation sensor.
Measuring the temperature of the body and the 
surface on forehead with infrared. Products the same
This appliance conforms to the following 
standards: 
EN60601-1: Medical electrical equipment Part 1: General 
                     requirements for safety
EN12470-5: Clinical thermometers Part 5: Performance of 
                     infrared ear thermometers (with maximum 
                     device)
93/42/EEC : Medical Device Directive 
ASTM E 1965-98: Standard Specification for Infrared
                             Thermometers for Intermittent 
                              Determination of Patient Temperature          
 IP is short for Ingress Protection which means that 
 Protection’s level.
Manufacturer 
Rerfer to the instructions
Equipment of BF
Recycling and Processing 
The european Union flag    
Connect iOS device via Bluetooth
 
1. Installation
Prior to first use, Download and install application to 
your iOS device. (Bluetooth 4.0 capabilities, 
e.g. iPhone 4S, iPhone 5, NewiPad and iPadMini).
2. Open application, and then press the Blood 
    Pressure icon on Measure screen.
3. Press the “Enter” button.  
4. Press the “Thermometer” button.
5. When the measurement is complete, the 
    temperature will display on Thermometer monitor & 
    save on iOS application screen.
6. This thermometer stores the last temperature 
    readings.    
Infrared  Thermometer