Beijing Noitom Technology Ltd. HI5-TC-01 User Manual

Page of 22
 
Hi5 VR Glove 
Developer Guidelines 
NOITOM corporation 
Dec.2017    V1.2 
 
Hi5 VR Glove Developer Guidelines
                                                                                                                           
3
 
 
2.2 Interaction Interfaces   
There is one button and one indicator light for each Glove and each Dongle. The 
interaction lookup table is as follows: 
 
Button Functions: 
 
Function 
Operation and Indication 
On Glove/Dongle 
Turning on the Glove 
Press the button when the Glove is 
powered off (click) 
Glove 
Turning off the Glove   
Press and hold the button for 5 
seconds (release after the indicator 
light turns off) 
Glove 
Entering pairing mode 
Press and hold the buttons for 3 
seconds (release when the indicator 
lights turn on to a solid state) 
Glove & Dongle 
Manually switching working 
frequency 
Short press the button (click) 
Dongle 
Triggering button event 
Short press the button (click) 
Glove 
( Table 2.2-1 ) 
 
Indicator Light States: 
 
Meaning 
Indicator Light State 
On Glove/Dongle 
Powered off 
Turned off 
Glove 
Standby 
Breathing 
Glove & Dongle 
Pairing mode 
1Hz flashing (slowly flashing) 
Glove & Dongle 
Working mode 
20Hz flashing (rapid flashing) 
Glove & Dongle 
The current ambient 
environment has magnetic 
interference 
Solid state turned on (in working 
mode) 
Glove 
Error 01 
(Self-test error) 
Solid state turned on (right after 
power on) 
Glove & Dongle 
Error 02 
(enter Boot mode) 
3s off, 0.1s on 
Glove & Dongle 
( Table 2.2-2 ) 
 
Notice:The indicator light on the Gloves will turn RED when the battery power is low.