SOYAL TECHNOLOGY CO. LTD. AR-837 User Manual

Page of 9
SOYAL
ACCESS CONTROL SYSTEM
®
AR-837
V140217
    
B. 
1
2
P1
P2
P4
P7
P5
P6
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
2
1
4
3
2
1
2 1
3 2 1
P2
P3
P6
P5
P7
P1
P4
1
2
3
4
5
6
7
8
9
10
CN6
CN5
CN7
CN8
CN3
CN13
CN4
Contents
2
User Guide
The communication wires and power line should NOT be bound in the same conduit or tubing.
Don’t equip reader and lock with the same power supply. The power for reader may be unstable when the lock is activating, that may cause a  
malfunction in the reader.
The standard installation: Door relay and lock use the same power supply, and reader should use another independent power supply.
Use AWG 22-24 Shielded Twist Pair to avoid star wiring, CAT 5 cable for TCP/IP connection
1.Tubing:
2.Wire selection:
3.Power supply:
1
Products
3
Terminal Cables
4
Tools
Notice
Connector Table (1)
Wire Application
Wire
Color
Description
Lock Relay
1
Blue White (N.O.)DC24V1Amp
2
Purple White (N.C.)DC24V1Amp
Lock Relay COM
3
White
(COM)DC24V1Amp
Door Contact
4
Orange
Negative Trigger Input
Exit Switch
5
Purple
Negative Trigger Input
Alarm Relay
6
Gray
N.O./N.C. Optional (by jumper)
Power
7
Thick Red DC 12V
8
Thick Black DC 0V
Cable:      CN4
P1
Wire Application
Wire
Color
Description
RS-485 for Lift
Controller
1
Thick Green RS-485(B-)
2
Thick Blue RS-485(A+)
Cable:      CN6
P4
Wire Application
Wire
Color
Description
Door Bell
1
Black White Transistor Output Max. 12V/100mA 
(Open Collector Active Low)
2
Black
DC 0V
Cable:   7 CN13
P7
Wire Application
Wire
Color
Description
Beeper
1
Pink
Beeper Output 5V/100mA, Low
LED
2
Yellow
Red LED Output 5V/20mA, Max
3
Brown
Green LED Output 5V/20mA, Max
Door Output
4
Blue White Transistor Output Max. 12V/100mA 
(Open Collector Active Low)
Wiegand
5
Thin Green Wiegand DAT: 0 Input
6
Thin Blue Wiegand DAT: 1 Input
WG Door Contact
7
Orange
Negative Trigger Input
WG  Exit Switch
8
Purple
Negative Trigger Input
P2
Cable:      CN5
A-1.Surface Mounted: Use a screwdriver to screw the 
mounting plate to the wall. A-2.Embedded: To dig a hole for                       
837(EF):128mmx109mm; and then, use a screwdriver to screw the 
mounting plate to the wall.  
Pull cable ends through the access hole in the mounting plate.  
Attach AR-837(E) or AR-837 (EF) to the mounting plate and install 
screws (supplied) into the holes at the bottom with the allen key.  
Apply power. LED (green) will light up with one beep.
Installation
AR-837 (EF):Fingerprint
Wire Application
Wire
Color
Description
Reserved
1
Red
 -- 
Security trigger signal 
2
Purple
Security trigger signal Output
Arming
3
Red White Arming Output
Duress
4
Yellow White Duress Output
P6
Cable:      CN8
Wire Application
Wire
Color
Description
Anti-Tamper Switch
1
Red
N.C.
2
Orange
COM
3
Yellow
N.O.
P5
Cable:      CN3
Water proof Strip
Screws
A-1.Surface  
       Mounted
A-2.Embedded