Unique Broadband Systems Ltd. DRU1KW User Manual

Page of 176
 
 Chapter 
Operation 
 
5.4.10 High Power Amplifier Power Supply Unit (HPA PSU) 
 
The HPA PSU rectifier front panel includes three (3) status LEDs to indicate rectifier 
operation and alarm conditions. 
 
Figure 5-5 HPA PSU Rectifier 
 
 
1)  HPA PSU Rectifier Status LED Indicators 
 
Table 5-8 HPA PSU Rectifier Status LED Indicators 
 
LED 
Color 
Description 
Green 
Rectifier is powered on and is operating under normal 
conditions.  Note: Comm Fault is possible. 
Green Blink 
Rectifier output is inhibited, preparing to deliver power, 
ramping up or in standby. 
Amber 
Rectifier output is limited to less than fully rated output 
power. 
Norm 
OFF 
Rectifier is powered off. 
ACF or Fail alarm is active. 
Amber 
AC input is out of range and the rectifier output is 
powered off. 
ACF 
OFF 
Normal, no fault operation (when Norm LED is Green). 
Red Rectifier 
failure or shutdown. 
Red Blink 
Communication failure with controller. 
Red Wink 
Fan failure. 
Fail 
OFF 
Normal, no fault operation (when Norm LED is Green). 
  Blink Timing shall be approximately 0.5 seconds ON and 0.5 seconds OFF. 
  Wink Timing shall be approximately 0.2 seconds ON and 2 seconds OFF. 
 
 
 
 
 
 
 
 
 
SX03-20000-01-M01 5-8